Pepperl+Fuchs, Inc.Германия
73100
ПроизводитсяG10 junction block, LED status indication, AS-Interface, and auxiliary power to 1x M12 round plug connector
Все аналоги
Полный отчётТехнические параметры
| Питание | |
|---|---|
| Current loading capacity | Rated current of the fuse: 1.6 A Continous operation: 1.2 A |
| Rated operating voltage | U e | 10 ... 32 V PELV ( AS-Interface , ext. auxiliary voltage AUX ) |
| Short-circuit current | I k | max. 50 A |
| Voltage drop | U d | ≤ 0.6 V |
| Характеристики по постоянному и переменному току | |
| Noise immunity | EN 61000-6-2:2005 |
| Noise immunity EN 61000-6-2:2005 Emitted interference EN 61000-6-4:2007 Degree of protection EN 60529:2000 | Noise immunity | EN 61000-6-2:2005 | Emitted interference | EN 61000-6-4:2007 | Degree of protection | EN 60529:2000 |
| Условия эксплуатации и корпус | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Contacts CuSn / Au Housing PBT PC Body PUR, black Cable PUR Mounting screw Stainless steel 1.4305 / AISI 303 | Contacts | CuSn / Au | Housing | PBT PC | Body | PUR, black | Cable | PUR | Mounting screw | Stainless steel 1.4305 / AISI 303 |
| Height | 22 mm |
| Height 22 mm Width 27.7 mm Length 40.5 mm | Height | 22 mm | Width | 27.7 mm | Length | 40.5 mm |
| Maximum permissible ambient temperature | max. 55 °C (max. 131 °F) |
| Maximum permissible ambient temperature max. 55 °C (max. 131 °F) | Maximum permissible ambient temperature | max. 55 °C (max. 131 °F) |
| Mounting screw | Stainless steel 1.4305 / AISI 303 |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Другое | |
| Body | PUR, black |
| Cable | PUR |
| Color | black |
| Connection | Flat cable AS-Interface: cable piercing method Flat cable ext. auxiliary voltage U AUX : Insulation penetration technology Plug connection: M12 x 1 socket (V1) |
| Construction type | Socket, straight Flat cable terminals AS-Interface/ext. auxiliary voltage |
| Contacts | CuSn / Au |
| Cores | 4 x 0.34 mm 2 |
| Degree of protection | EN 60529:2000 |
| EMC Directive 2004/108/EC | EN 61000-6-2:2005, EN 61000-6-4:2007 |
| EMC Directive 2004/108/EC EN 61000-6-2:2005, EN 61000-6-4:2007 | EMC Directive 2004/108/EC | EN 61000-6-2:2005, EN 61000-6-4:2007 |
| Emitted interference | EN 61000-6-4:2007 |
| Housing | PBT PC |
| LED FAULT | LED red: Fuse unit blown |
| LED PWR | LED green: normal operation |
| Length | L | 2 m |
| Mass | 100 g |
| Overload protection | Fuse acc. to UL248-1, UL248-14 |
| Protection class | III |
| Sheath diameter | ∅4,3 mm |
| Sheath diameter ∅4,3 mm Color black Cores 4 x 0.34 mm 2 Length L 2 m | Sheath diameter | ∅4,3 mm | Color | black | Cores | 4 x 0.34 mm 2 | Length | L | 2 m |
| Surge protection | U e : Over voltage category III, safe isolated power supplies (PELV) |
| Tightening torque, cable gland | 0.4 Nm |
| Tightening torque, fastening screws | 1.65 Nm |
| UL approval | cULus Listed, Type 1 enclosure |
| UL File Number | E223772 "For use in NFPA 79 Applications only" |
| Width | 27.7 mm |
Изображения