Все аналоги
Полный отчётТехнические параметры
| Питание | |
|---|---|
| Current | max. 240 mA |
| Nominal voltage | U o | 8.2 V (R i approx. 1 kΩ) |
| Voltage | max. 32 V DC |
| Характеристики по постоянному и переменному току | |
| Switching frequency | f | 0 ... 3 kHz |
| Time delay before availability | t v | ≤ 1.1 ms |
| Условия эксплуатации и корпус | |
| Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
| Height | 35.5 mm |
| Height 35.5 mm Width 65 mm Length 77.5 mm | Height | 35.5 mm | Width | 65 mm | Length | 77.5 mm |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
| Другое | |
| Actual operating distance | s r | 2.7 ... 3.3 mm typ. |
| Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm |
| Assured operating distance | s a | 0 ... 2.4 mm |
| Connection (system side) | Cage tension spring terminals Stripped length 7 mm M20 x 1.5 cable gland usable thread length 11.5 mm screw-in depth max. 11.5 mm |
| Connection (valve side) | Cage tension spring terminals |
| Control drawing | 116-0456 |
| Core cross section (system side) | 1.5/2.5 mm 2 flexible/rigid |
| Core cross section (valve side) | 1.5/2.5 mm 2 flexible/rigid |
| Degree of protection | IP66 / IP67 |
| Diagnostic Coverage (DC) | 0 % |
| Electromagnetic compatibility | NE 21:2007 |
| Equipment protection level Ga | IECEx TUN 17.0021X |
| Equipment protection level Ga IECEx TUN 17.0021X Equipment protection level Gb IECEx TUN 17.0021X Equipment protection level Mb IECEx TUN 17.0021X | Equipment protection level Ga | IECEx TUN 17.0021X | Equipment protection level Gb | IECEx TUN 17.0021X | Equipment protection level Mb | IECEx TUN 17.0021X |
| Equipment protection level Ga TÜV 99 ATEX 1479 X Equipment protection level Gb TÜV 99 ATEX 1479 X Equipment protection level Gc (ic) PF13CERT2895 X | Equipment protection level Ga | TÜV 99 ATEX 1479 X | Equipment protection level Gb | TÜV 99 ATEX 1479 X | Equipment protection level Gc (ic) | PF13CERT2895 X |
| Equipment protection level Gb | IECEx TUN 17.0021X |
| Equipment protection level Gc (ic) | PF13CERT2895 X |
| Equipment protection level Mb | IECEx TUN 17.0021X |
| Hazardous Location | E501628 |
| Hazardous Location 2020322315002262 | Hazardous Location | 2020322315002262 |
| Housing material | PBT |
| Hysteresis | H | typ. 5 % |
| Installation | flush mountable |
| Length | 77.5 mm |
| Measuring plate detected | ≤ 1 mA |
| Measuring plate not detected | ≥ 3 mA |
| Measuring plate not detected ≥ 3 mA Measuring plate detected ≤ 1 mA | Measuring plate not detected | ≥ 3 mA | Measuring plate detected | ≤ 1 mA |
| Mission Time (T M ) | 20 a |
| MTTF d | 1470 a |
| NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Electromagnetic compatibility NE 21:2007 Standards EN IEC 60947-5-2 | NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Electromagnetic compatibility | NE 21:2007 | Standards | EN IEC 60947-5-2 |
| NEPSI certificate | GYJ19.1410X |
| NEPSI certificate GYJ19.1410X | NEPSI certificate | GYJ19.1410X |
| Note | LED switch-off |
| Ordinary Location | E87056 |
| Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0456 | Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0456 |
| Output type | NAMUR |
| Rated operating distance | s n | 3 mm |
| Reduction factor r 304 | 1 |
| Reduction factor r Al | 0.5 |
| Reduction factor r Brass | 0.6 |
| Reduction factor r Cu | 0.4 |
| Reduction factor r St37 | 1.3 |
| Reverse polarity protection | reverse polarity protected |
| Safety Integrity Level (SIL) | SIL 2 |
| Sensing face | PBT |
| Short-circuit protection | yes |
| Standards | EN IEC 60947-5-2 |
| Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
| Switching function | 2 x normally closed (NC) |
| Switching state indicator | LED, yellow |
| Tightening torque, cable gland | M20 x 1.5 ; max. 7 Nm M12 x 1.5 ; max. 1.5 Nm |
| Tightening torque, fastening screws | ≤ 5 Nm |
| Tightening torque, housing screws | 1 Nm |
| UL approval | cULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC |
| Use in the hazardous area | see instruction manuals |
| Valve status indicator | LED, yellow |
| Width | 65 mm |
Изображения
Документы
К этому компоненту пока не привязаны документы.