Все аналоги
Полный отчётТехнические параметры
| Питание | |
|---|---|
| No-load supply current | I 0 | ≤ 10 mA |
| Operating current | I L | 0 ... 200 mA |
| Operating voltage | U B | 10 ... 60 V DC |
| Voltage drop | U d | ≤ 2.5 V |
| Характеристики по постоянному и переменному току | |
| Switching frequency | f | 0 ... 1500 Hz |
| Условия эксплуатации и корпус | |
| Ambient temperature | -35 ... 80 °C (-31 ... 176 °F) |
| Другое | |
| Assured operating distance | s a | 0 ... 1.22 mm |
| Bending radius | > 10 x cable diameter |
| Cable diameter | 4.6 mm ± 0.2 mm |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Color | grey |
| Connection type | cable |
| Core cross section | 0.34 mm 2 |
| Degree of protection | IP67 |
| Diagnostic Coverage (DC) | 0 % |
| Diameter | 18 mm |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Hysteresis | H | 1 ... 10 % typ. 5 % |
| Installation | flush |
| Length | L | 2 m |
| Length 57 mm Diameter 18 mm | Length | 57 mm | Diameter | 18 mm |
| Mass | 146 g |
| Material | PVC |
| Mission Time (T M ) | 20 a |
| MTTF d | 1240 a |
| Number of cores | 3 |
| Operating pressure | 350 bar (5076.4 psi) |
| Output polarity | DC |
| Output type | PNP |
| Rated operating distance | s n | 1.5 mm |
| Reduction factor r 304 | 0.5 |
| Reverse polarity protection | reverse polarity protected |
| Sensing face | Epoxy (black) |
| Short-circuit protection | pulsing |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Switching function | Normally open (NO) |
| UL approval | cULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA |
| Wire end ferrules | yes |
Изображения
Документы