Технические параметры

Питание
Nominal voltageU o | 8.2 V (R i approx. 1 kΩ)
Характеристики по постоянному и переменному току
Switching frequencyf | 0 ... 300 Hz
Условия эксплуатации и корпус
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Другое
ANZEx18.3018X
Assured operating distances a | 0 ... 8.1 mm
Bending radius> 10 x cable diameter
Cable diameter6 mm ± 0.2 mm
Cable diameter 6 mm ± 0.2 mm Bending radius > 10 x cable diameter Material PVC Core cross section 0.75 mm 2 Length L 5 mCable diameter | 6 mm ± 0.2 mm | Bending radius | > 10 x cable diameter | Material | PVC | Core cross section | 0.75 mm 2 | Length | L | 5 m
CML approvalon request
Connection typecable
Control drawing116-0452
Core cross section0.75 mm 2
Degree of protectionIP66 / IP67
Diameter30 mm
Equipment protection level DaIECEx PTB 11.0037X
Equipment protection level GaIECEx PTB 11.0037X
Equipment protection level Ga PTB 00 ATEX 2048 X Equipment protection level Gb PTB 00 ATEX 2048 X Equipment protection level Da PTB 00 ATEX 2048 XEquipment protection level Ga | PTB 00 ATEX 2048 X | Equipment protection level Gb | PTB 00 ATEX 2048 X | Equipment protection level Da | PTB 00 ATEX 2048 X
Equipment protection level GbIECEx PTB 11.0037X
Equipment protection level MbIECEx PTB 11.0037X
Hazardous LocationE501628
Hazardous Location 19-AV4BO-0227Hazardous Location | 19-AV4BO-0227
Hazardous Location 2020322315002255Hazardous Location | 2020322315002255
Housing materialStainless steel 1.4305 / AISI 303
Installationflush
LengthL | 5 m
Length 40 mm Diameter 30 mmLength | 40 mm | Diameter | 30 mm
MaterialPVC
Measuring plate detected≤ 1 mA
Measuring plate not detectedmin. 3 mA
Measuring plate not detected min. 3 mA Measuring plate detected ≤ 1 mAMeasuring plate not detected | min. 3 mA | Measuring plate detected | ≤ 1 mA
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2
Ordinary LocationE87056
Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0452Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0452
Output typeNAMUR
Rated operating distances n | 10 mm
Reduction factor r 3040.85
Reduction factor r Al0.4
Reduction factor r Cu0.3
Safety Integrity Level (SIL)SIL 2
Scope of delivery2 self locking nuts in scope of delivery
Sensing facePBT
StandardsEN IEC 60947-5-2
Switching functionNormally closed (NC)
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Use in the hazardous areasee instruction manuals