Поиск аналогов электронных компонентов
103846
Pepperl+Fuchs, Inc.Германия

103846

Производится

Inductive sensor

Спросить AI FAE

Все аналоги

Полный отчёт

Технические параметры

Питание
Nominal voltageU o | 8.2 V (R i approx. 1 kΩ)
Характеристики по постоянному и переменному току
Switching frequencyf | 0 ... 200 Hz
Условия эксплуатации и корпус
Ambient temperature-40 ... 100 °C (-40 ... 212 °F)
Другое
Assured operating distances a | 0 ... 6.48 mm
Bending radius> 10 x cable diameter
Cable diameter6 mm ± 0.2 mm
Connection typecable
Control drawing116-0454
Core cross section0.75 mm 2
Degree of protectionIP68
Diagnostic Coverage (DC)0 %
Diameter18 mm
Equipment protection level DaIECEx PTB 11.0092X
Equipment protection level Dc (tc)IECEx TUR 21.0018X
Equipment protection level GaIECEx PTB 11.0092X
Equipment protection level GbIECEx PTB 11.0092X
Equipment protection level Gc (ec)IECEx TUR 21.0017X
Equipment protection level MbIECEx PTB 11.0092X
Hazardous LocationE501628
Hazardous Location 2020322315002308 2024322315005947 2024322315005860Hazardous Location | 2020322315002308 2024322315005947 2024322315005860
Housing materialCrastin (PBT), black
Installationnon-flush
LengthL | 50 m
Length 39 mm Diameter 18 mmLength | 39 mm | Diameter | 18 mm
Materialsilicone
Measuring plate detected≤ 1 mA
Measuring plate not detected≥ 3 mA
Measuring plate not detected ≥ 3 mA Measuring plate detected ≤ 1 mAMeasuring plate not detected | ≥ 3 mA | Measuring plate detected | ≤ 1 mA
Mission Time (T M )20 a
MTTF d11850 a
NAMUREN 60947-5-6:2000 IEC 60947-5-6:1999
NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Standards EN IEC 60947-5-2NAMUR | EN 60947-5-6:2000 IEC 60947-5-6:1999 | Standards | EN IEC 60947-5-2
Ordinary LocationE87056
Ordinary Location E87056 Hazardous Location E501628 Control drawing 116-0454Ordinary Location | E87056 | Hazardous Location | E501628 | Control drawing | 116-0454
Output typeNAMUR with safety function
Rated operating distances n | 8 mm
Reduction factor r 3040.85
Reduction factor r Al0.4
Reduction factor r Cu0.3
Scope of deliverySupplied with 2 nuts
Sensing faceCrastin (PBT), black
StandardsEN IEC 60947-5-2
Switching functionNormally closed (NC)
UL approvalcULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 8.2 V DC
Use in the hazardous areasee instruction manuals
Wire end ferrulesyes
Wire end ferrules yes Cable diameter 6 mm ± 0.2 mm Bending radius > 10 x cable diameter Material silicone Core cross section 0.75 mm 2 Length L 50 mWire end ferrules | yes | Cable diameter | 6 mm ± 0.2 mm | Bending radius | > 10 x cable diameter | Material | silicone | Core cross section | 0.75 mm 2 | Length | L | 50 m

Изображения

Документы