Results forCD4541

27 parts

Product search results27 total

  • CD4541

  • CD4541

    Gates and Inverters

    芯伯乐XBLW为您提供国产型号CD4541的封装、参数规格、替代方案、数据手册等信息;免费样品、技术方案支持请咨询本公司

  • CD4541BE

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14DIP

  • CD4541BCMX

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14SOIC

  • CD4541BMTG4

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14SOIC

  • CD4541BM96E4

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14SOIC

  • CD4541BM96G4

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14SOIC

  • CD4541BNSRG4

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14SO

  • CD4541BPWRG4

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14TSSOP

  • CD4541B

    Parity Generators and Checkers

    CD4541B programmable timer consists of a 16-stage binary counter, an oscillator that is controlled by external R-C components (2 resistors and a capacitor), an automatic power-on reset circuit, and output control logic. The counter increments on positive-edge clock transitions and can also be reset via the MASTER RESET input. The output from this timer is the Q or Q\ output from the 8th, 10th, 13th, or 16th counter stage. The desired stage is chosen using time-select inputs A and B (see Frequency Select Table). The output is available in either of two modes selectable via the MODE input, pin 10 (see Truth Table). When this MODE input is a logic "1", the output will be a continuous square wave having a frequency equal to the oscillator frequency divided by 2 N . With the MODE input set to logic "0" and after a MASTER RESET is initiated, the output (assuming Q output has been selected) changes from a low to a high state after 2 N-1 counts and remains in that state until another MASTER RESET pulse is applied or the MODE input is set to a logic "1". Timing is initialized by setting the AUTO RESET input (pin 5) to logic "0" and turning power on. If pin 5 is set to logic "1", the AUTO RESET circuit is disabled and counting will not start until after a positive MASTER RESET pulse is applied and returns to a low level. The AUTO RESET consumes an appreciable amount of power and should not be used if low-power operation is desired. For reliable automatic power-on reset, V DD should be greater than 5V. The RC oscillator, shown in Figure 2, oscillates with a frequency determined by the RC network and is calculated using: Where f is between 1kHz and 100kHz and R S and 2R TC .

  • CD4541B

    Gates and Inverters

    可编程定时器

  • CD4541▲

    Gates and Inverters

  • CD4541BE

    Programmable Timers and Oscillators

    BINARY COUNTER

  • CD4541BF

    Programmable Timers and Oscillators

    PROGRAMMABLE TIMER

  • CD4541BM

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14SOIC

  • CD4541BCM

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14SOIC

  • CD4541BCN

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14DIP

  • CD4541BEX

    Programmable Timers and Oscillators

    PROGRAMMABLE TIMER

  • CD4541BFX

    Programmable Timers and Oscillators

    PROGRAMMABLE TIMER

  • CD4541BMT

    Programmable Timers and Oscillators

    IC OSC PROG TIMER 100KHZ 14SOIC

Showing 1–20 of 27

Can't find your part?

Our AI can look it up on the web and add it to the catalog. Or tell our team directly.

0 of 2 selected