Поиск аналогов электронных компонентов
43708
Pepperl+Fuchs, Inc.Германия

43708

Производится

Inductive sensor

Подобрать аналогСпросить AI FAE

Все аналоги

Полный отчёт

Технические параметры

Питание
No-load supply currentI 0 | ≤ 20 mA
Off-state currentI r | 0 ... 0.5 mA
Operating currentI L | 0 ... 200 mA
Operating voltageU B | 10 ... 60 V DC
Operating voltage indicatorLED, green
Voltage dropU d | ≤ 2 V
Характеристики по постоянному и переменному току
Switching frequencyf | 0 ... 200 Hz
Условия эксплуатации и корпус
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Height40 mm
Height 40 mm Width 40 mm Length 118 mmHeight | 40 mm | Width | 40 mm | Length | 118 mm
Другое
Actual operating distances r | 18 ... 22 mm typ. 20 mm
Assured operating distances a | 0 ... 16.2 mm
CCC approvalCertified by China Compulsory Certification (CCC)
Connection typescrew terminals
Core cross sectionup to 2.5 mm 2
Degree of protectionIP68 / IP69K
Diagnostic Coverage (DC)0 %
E1 Type approval10R-04
Fire protectionrequirements of hazard level 1 to 3 (HL1 - HL3) according to DIN EN 45545-2 R26
Housing baseplastic
Housing materialPA/metal with epoxy powder coating
HysteresisH | typ. 5 %
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Installationflush
Length118 mm
Mass225 g
Maximum core cross-sectionwithout wire end ferrules 2.5 mm 2 , with connector sleeves 1.5 mm 2
Minimum core cross-sectionwithout wire end ferrules 0.5 mm 2 , with connector sleeves 0.34 mm 2
Mission Time (T M )20 a
MTTF d670 a
NoteTightening torque: 1.8 Nm (housing)
Output polarityDC
Output typeNPN
Rated operating distances n | 20 mm
Reduction factor r 3040.77
Reduction factor r Al0.34
Reduction factor r Brass0.43
Reduction factor r Cu0.32
Reduction factor r St371
Reverse polarity protectionreverse polarity protected
Sensing facePA-GF35
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2 Fire protection requirements of hazard level 1 to 3 (HL1 - HL3) according to DIN EN 45545-2 R26Standards | EN IEC 60947-5-2 | Fire protection | requirements of hazard level 1 to 3 (HL1 - HL3) according to DIN EN 45545-2 R26
Switching functioncomplementary
Switching state indicatorLED, yellow
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA
Width40 mm

Изображения

Документы

К этому компоненту пока не привязаны документы.