Все аналоги
Полный отчётТехнические параметры
| Питание | |
|---|---|
| No-load supply current | I 0 | ≤ 55 mA |
| Operating voltage | U B | 15 ... 30 V DC , ripple 10 % SS |
| Характеристики по постоянному и переменному току | |
| Load impedance | ≥ 1 kOhm |
| Repeat accuracy | ± 0.1 % of full-scale value |
| Resolution | 0.47 mm |
| Response delay | ≤ 150 ms |
| Transducer frequency | approx. 175 kHz |
| Условия эксплуатации и корпус | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Height | 31 mm |
| Height 31 mm Width 105 mm Length 25 mm | Height | 31 mm | Width | 105 mm | Length | 25 mm |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Temperature influence | ± 1.5 % of full-scale value |
| Другое | |
| Adjustment range | 100 ... 2000 mm |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Common mode operation | max. 33 Hz |
| Common mode operation max. 33 Hz Multiplex operation ≤ 33 / n Hz, n = number of sensors | Common mode operation | max. 33 Hz | Multiplex operation | ≤ 33 / n Hz, n = number of sensors |
| Connection type | Connector plug M12 x 1 , 5-pin |
| Dead band | 0 ... 80 mm |
| Default setting | evaluation limit A1: 100 mm evaluation limit A2: 2000 mm |
| Degree of protection | IP65 |
| Deviation of the characteristic curve | ± 1 % of full-scale value |
| Housing | ABS |
| Housing ABS Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam | Housing | ABS | Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Input type | 1 program input lower evaluation limit A1: -U B ... +1 V, upper evaluation limit A2: +4 V ... +U B input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s |
| LED green | solid green: monitoring system green flashing: program function |
| LED red | flashing: normal mode: error Program function: no object detected permanently: Program mode, object uncertain |
| LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
| Length | 25 mm |
| Mass | 100 g |
| Multiplex operation | ≤ 33 / n Hz, n = number of sensors |
| Output type | 1 analog output 0 ... 10 V |
| Sensing range | 80 ... 2000 mm |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 | Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standard target plate | 100 mm x 100 mm |
| Synchronization | 1 synchronous input 0-level: -U B ...+1 V 1-level: +4 V...+U B input impedance: > 12 KOhm synchronization pulse: 0,1 ... 28 ms |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| UL approval | cULus Listed, General Purpose |
| Width | 105 mm |
Изображения
Документы
К этому компоненту пока не привязаны документы.