All alternatives

View full report

Technical parameters

AC and DC characteristics
Resolution, selectable70 mm, 50 mm
Scan angle, resolution275°, 0.2°
Environment and package
Dimensions80 x 80 x 86 mm (W x H x D)
Other
Configurable field sets (1 protective field and 2 warning fields)1 / 8 / 32
ConnectionM12 connector, 8- or 12-pin | for Ethernet TCP/IP: M12 connector, 4-pin
Measurement value output via UDPDistance and signal strength | Operating range 25 m | ROS driver (version 1 and version 2)
Protective field operating range3 m
SafetyType 3, performance level PL d, SIL 2
Warning field operating range15 m

Documents