All alternatives

View full report

Technical parameters

Datasheet-verified parameters

8 items
ParameterValue and test conditionsSource
Pressure Range20 TO 250 kPA (2.9 TO 36.3 psi)
Output Voltage0.2 TO 4.9 V
Maximum Error1.5% Over 0° to 85°C
Temperature Compensation Range-40° to +125°C
PackageUnibody Package (Case 867)
Operating Temperature-40° to +125°C
Supply Voltage+5 V
MediaDry Air
All parameters (8)ExpandCollapse
Power
Supply Voltage4.85 to 5.35 VDC
AC and DC characteristics
Accuracy±1.5 %VFSS (Max)
Environment and package
Operating Temperature-40 to +125 °C
PackageUnibody (Case 867)
Other
Differential Pressure Range20 to 250 kPa
Maximum Pressure1000 kPa
Response Time1.0 msec (Typ)
Sensitivity20 mV/kPa (Typ)

Pinout and package

PackageUnibody Package (Case 867)

PinNameFunctionSource
1V_OUT(Output)
2GND(Ground)
3V_S(Supply)
4N/C(Internal connection, do not connect to external circuitry)
5N/C(Internal connection, do not connect to external circuitry)
6N/C(Internal connection, do not connect to external circuitry)

Documents

Datasheet-verified content is extracted by AI from the manufacturer datasheet. Click a page number to view the original.