All alternatives

View full report

Technical parameters

Power
Input Power100 W CW Max @ -55 to +85 °C 1 KW Peak Min +85 °C (1 µs PW, 0.1% Duty Cycle 100 W (1 µs PW, 1% Duty Cycle, 10 KHz) 100 W (10 µs PW, 0.1% Duty Cycle, 100 Hz) 100 W (1 µs PW, 0.1% Duty Cycle, 1 KHz) 100 W (40 µs PW, 10% Duty Cycle, 2.5 KHz)
Power Handling100 W CW Max 1 KW Peak Min (1 µs PW, 0.1% Duty Cycle
AC and DC characteristics
Frequency Max (GHz)15
Frequency Min (GHz)0.02
Frequency Range (GHz)0.02 to 15
Environment and package
Non-Operating Temperature-55 °C to +125 °C
Operating Temperature-40 °C to +85 °C
Size0.90" x 0.38" x 0.38" (Excluding Connectors)
Temperature CycleMIL-STD-202, METHOD 107D COND. A
Other
AltitudeMIL-STD-202, METHOD 105C COND. B
Connectors In/OutSMA Male / Female
Export Classification (ECCN)EAR99
FinishPainted Blue
HumidityMIL-STD-202, METHOD 103B COND. B
Input/Output VSWR2.0:1 Max @ -10 dBm Input Power
Insertion Loss (dB)1.6 Max @ -10 dBm Input Power
P1dB Limiting Threshold (dBm)5 Min
Recovery Time100 ns Max @ 1 kW Peak Power
RF Leakage (dBm)15 dBm Max @ 100 W CW
ShockMIL-STD-202, METHOD 213B COND. B
StatusActive
VibrationMIL-STD-202, METHOD 204D COND. B
Weight20 g (0.705 oz) Max

Documents