All alternatives

View full report

Technical parameters

Power
*1 Dielectric strength test voltageVISO | According to UL standard 60950-1 second edition, Agency type test is 60 seconds | 4800 | VAC
Operating voltage (basic insulation)VWFSI | Basic (single) isolation according to UL standard 60950-1, 2nd Edition | 990 | VDC or Vpk
Operating voltage (enhanced insulation)VWFRI | Enhanced (double) isolation according to UL standard 60950-1, 2nd Edition | 636 | VDC or Vpk
Output currentIOUT | ±40 | mA
Output voltageVOUT | 0.15 to VCC-0.15 | V
Output voltage range @IPVOUT-VQVO | RCTxxxBF
Primary current measurement rangeIP | 0 | 50 | A
Supply currentICC | 18 | mA
Supply voltageVCC | -0.3 to 4.6 | V
Zero current outputVQVO | RCTxxxBF | TA = 25°C | 1.65
AC and DC characteristics
bandwidthBW | Small signal –3dB, CL=1nF, TA=25°C | 120 | 170 | KHz
Output impedanceROUT | TA = 25°C | – | 3 | – | Ω
Power-on delayTPO | TA=25°C | 80 | μs
Zero magnetic offset currentIP=0A, TA=25°C, after excursion of | mA
Zero offset currentIOFFSET | TA=25°C | 0.15 | A
Zero offset voltageIP=0A,TA=25°C | -4 | ±3 | 4 | mV
Environment and package
Maximum junction temperatureTJ | 165 | ℃
Operating temperatureTA | -40 to 150 | ℃
Storage temperatureTS | -55 to 165 | ℃
Other
CharacteristicSymbol | Rating | Unit
Linearity errorLinERR | Of full rang | -1 | 0.5 | 1 | %
Load capacitanceCL | VOUT TO GND | 6 | 100 | nF
Load resistanceRL | VOUT to VCC or GND | 2 | KΩ
QVO follow-up error (-R)Er | -0.3 | 0.3 | %
RCT050BF-31.65 | 26.4 | PFF, PSF PSS, SMT | 40 | 400
RCT050BR-3VCC/2 | ±50
RCT050UF-30.5 | 50 | 49.4 | 40 | 400
RCT100BF-31.65 | ±100 | 13.2 | PFF, PSF PSS, SMT | 40 | 400
RCT100BR-3VCC/2
RCT100UF-30.5 | 100 | 24.7 | 40 | 400
RCT150BF-31.65 | ± 150 | 8.8 | PFF, PSF PSS, SMT | 40 | 400
RCT150BR-3VCC/2
RCT150UF-30.5 | 150 | 16.5 | 40 | 400
RCT200BF-31.65 | ±200 | 6.6 | PFF, PSF PSS, SMT | 40 | 400
RCT200BR-3VCC/2
RCT200UF-30.5 | 200 | 12.4 | 40 | 400
RCT250BF-31.65 | ±250 | 5.3 | PFF, PSF PSS, SMT | 40 | 400
RCT250BR-3VCC/2
RCT250UF-30.5 | 250 | 9.9 | 40 | 400
Response timetRESPONSE | TA=25°C, CL=1nF, IP step=50% of IP+, 90% input to 90% output | 3 | μs
Sensitivity errorESens | @TA=25°C;VCC=3.3V | -1 | 1 | %
Sensor sensitivitySensTA | @VCC=3.3V | 49.4 | mV/A
Total output errorETOT(HT) | Full scale of IP, TA=25°C~125°C | -2 | 2 | %
TypeZero point voltage VOUT(Q) (V) | Primary current rangeIP (A) | sensitivity Sens(Typ.)(mV/A) | Encapsulation form | MPQ(PCS) | MOQ(PCS)