Power
耐电压 voltage proof极间 between terminals | 1.6*U R ( VDC ) /10s
问:BM电容器电压单位是什么?答:BM电容器电压单位有:VAC(交流电压)和VDC(直流电压)。
额定电压 Rated voltage250VDC(125VAC), 400VDC(220VAC),630VDC(250VAC)
AC and DC characteristics
电压爬升率 Pulse rise time(dv/dt)60V/ μs Max
Environment and package
极壳 between terminals and case2*U R +1500 ( VAC ) / 60s (2000VAC min)
问:BM电容器使用寿命如何分等级?答:根据CQC标准,CBB电容的使用寿命等级分四个等级,使用(连续运行)寿命如下:
问:BM电容器常规安装方式有哪些?答: BM电容器的安装方式有:正耳、无耳、弯插铁耳、直插铁耳、侧长耳、中双耳、对角底双耳、平口双耳。 (如图二)
额定 温度 Rated temperature85 ℃ Max
Other
0.47 μF18.0 | 8.5 | 14.5 | 15.0 | 0.8 | 1.0 μF | 26.3 | 13.0 | 23.0 | 22.5 | 0.8
0.68 μF18.0 | 10.0 | 18.0 | 15.0 | 0.8 | 1.0 μF | 31.5 | 10.8 | 21.6 | 27.5 | 0.8
1.0 μF26.3 | 7.0 | 16.5 | 22.5 | 0.8 | 2.2 μF | 31.5 | 13.0 | 21.6 | 27.5 | 0.8
1.2 μF26.3 | 7.0 | 16.5 | 22.5 | 0.8 | 630VDC(250VAC)
1.5 μF26.5 | 8.5 | 17.0 | 22.5 | 0.8 | 0.47 μF | 26.3 | 8.5 | 17.0 | 22.5 | 0.8
250VDC(125VAC)2.0 μF | 31.5 | 10.8 | 19.5 | 27.5 | 0.8
400VDC(220VAC)0.68 μF | 26.3 | 10.0 | 19.0 | 22.5 | 0.8
C R >1 μF≤ 0.002(1KHz)
Rated Cap.L | W | H | P | Ф d | Rated Cap. | L | W | H | P | Ф d
容量偏差 Capacitance tolerance±5%(J) 、 ±10%(K)
容量范围 Capacitance range0. 22 μF ~ 3.3 μF
引用 标准 Reference standardGB /T 14 579,IEC60384-17
损耗角切 Tangent of loss angle (20 ℃ )C R ≤ 1 μF | ≤ 0.001(1KHz); ≤ 0.003(10KHz)
气候类别 Climatic category40/105/21
绝缘电阻 Insulation resistance (20 ℃ )极间 between terminals | ≥ 30 000MΩ , C R ≤0.33μF (100Vdc,60s) ≥ 75 00 S , C R >0.33μF (100Vdc,60s)
问:BM电容器MKPH、MKPH-R、MKPH-S,MKP-L表示的是什么类型的电容?答:BM电容中MKPH表示的是高压谐振电容器;MKPH-R表示的是工业类谐振电容器;MKPH-S表示的是工业类缓冲吸收电容器;MKP-L表示的是工业类滤波电容器。
问:BM电容器容量的单位是什么?各个单位如何转换?答:BM电容器容量单位是F(法拉)。 F(法拉)的转换公式是: 1F(法拉)=100000μF(微法) 1μF(微法)=100000pF(皮法) F的量是很大的,一般用μF和pF做电容的单位。
问:BM电容器常规外表颜色表示什么意思?答:BM电容器为了区分环保产品和非环保产品,对电容器外表以不同的颜色来表示。其中黑色表示非环保产品;蓝色、灰白色、黄色、褐色表示环保产品。
问:BM电容器的主要参数是什么?答:BM电容器的主要参数有容量和电压。
问:CBB是什么意思?答:CBB是中国对金属化聚丙烯薄膜电容的简称。