All alternatives

View full report

Technical parameters

Power
Momentary current (20 ms, 0.1 Hz)0 ... 1200 mA
Off-state currentI r | typ. 0.7 mA
Operating currentI L | 5 ... 200 mA
Operating voltageU B | 20 ... 253 V
Voltage dropU d | typ. 4 V at 15 ... 200 mA typ. 6.5 V at 5 mA
AC and DC characteristics
Switching frequencyf | 0 ... 20 Hz
Time delay before availabilityt v | ≤ 30 ms
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Other
Assured operating distances a | 0 ... 1.62 mm
Bending radius> 10 x cable diameter
Cable diameter4.6 mm ± 0.2 mm
CCC approvalCertified by China Compulsory Certification (CCC)
Colorgrey
Connection typecable
Core cross section0.34 mm 2
CSA approvalcCSAus Listed, General Purpose
Degree of protectionIP67
Diameter12 mm
Housing materialStainless steel 1.4305 / AISI 303
Installationflush
LengthL | 2 m
Length 50 mm Diameter 12 mmLength | 50 mm | Diameter | 12 mm
MaterialPVC
Note1) In the temperature range below 0 °C, permissible operating voltage U b 80...253 V Safety fuse ≤ 2 A (quick-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
Number of cores3
Output polarityAC
Output typeTwo-wire
Rated operating distances n | 2 mm
Reduction factor r 3040.6
Reduction factor r Al0.1
Reduction factor r Cu0.1
Reverse polarity protectionreverse polarity tolerant
Scope of delivery2 self locking nuts in scope of delivery
Sensing facePBT
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorLED, yellow
UL approvalcULus Listed Load Type: Resistive Enclosure Type Rating: Type 1
Wire end ferrulesyes

Documents