All alternatives

View full report

Technical parameters

Environment and package
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area
Design / MountingOutside installation
Mountingwall mounting
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Approved forEx ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db
Approved for Ex ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C DbApproved for | Ex ib [ia Ga] IIC T4 Gb , Ex ic [ia Ga] IIC T4 Gc , Ex ec [ia Ga] IIC T4 Gc , [Ex ia Ma] I , [Ex ia Da] IIIC , Ex tb [ia Da] IIIC T130 °C Db
Busup to 2.5 mm 2
Bus up to 2.5 mm 2 Inputs up to 2.5 mm 2Bus | up to 2.5 mm 2 | Inputs | up to 2.5 mm 2
Cable diametersee table 2
Cable glandsensor inputs M16, fieldbus M20
Connection typeplug-in terminals , spring terminal and screw terminal
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Degree of protectionIEC 60529
Directive 2014/30/EUEN 61326-1:2013
Directive 2014/30/EU EN 61326-1:2013Directive 2014/30/EU | EN 61326-1:2013
Directive 2014/34/EUEN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
Directive 2014/34/EU EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014Directive 2014/34/EU | EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012 , EN 60079-31:2014
Directive 2014/35/EUEN 61010-1:2010
Directive 2014/35/EU EN 61010-1:2010Directive 2014/35/EU | EN 61010-1:2010
Electromagnetic compatibilityNE 21:2011
Electronic componentBinary multi-input/output R8D0-MIO-Ex12.FF* For technical data on installed electronic component see datasheet.
EU-type examination certificateBVS 16 ATEX E 075 X
Fieldbus standardIEC 61158-2
Fieldbus typeFOUNDATION Fieldbus
FM approvalpending
Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V
Galvanic isolationEN 60079-11
Housing materialAluminum
IECEx approvalIECEx BVS 16.0051X
Inputsup to 2.5 mm 2
Installation in hazardous areaZone 1 / Div. 1
Marine approvalpending
MarkingII 2 (1) G Ex ib [ia Ga] IIC T4 Gb , [exsign] II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , [exsign] II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , [exsign] I (M1) [Ex ia Ma] I , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 2 (1) D Ex tb [ia Da] IIIC T130 °C Db
Mass1800 g
Number of inputs12
Relative humidity≤ 95 % non-condensing
Shock resistanceEN 60068-2-27
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Vibration resistanceEN 60068-2-6

Documents

No documents are linked to this part yet.