All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | ≤ 50 mA |
| Operating voltage | U B | 10 ... 30 V DC , ripple 10 % SS |
| Output current | < 12 mA |
| AC and DC characteristics | |
| 0 Level 0 ... 1 V 1 Level 4 V ... U B Input impedance > 12 kΩ Output current < 12 mA Pulse length 0.5 ... 300 ms (level 1) Pulse interval ≥ 33 ms (level 0) | 0 Level | 0 ... 1 V | 1 Level | 4 V ... U B | Input impedance | > 12 kΩ | Output current | < 12 mA | Pulse length | 0.5 ... 300 ms (level 1) | Pulse interval | ≥ 33 ms (level 0) |
| Input impedance | > 12 kΩ |
| Load impedance | ≤ 500 Ω at U B ≥ 14V ≤ 300 Ω at U B < 14V |
| Repeat accuracy | ≤ 0.1 % of full-scale value |
| Resolution | Evaluation range [mm]/3200, however ≥ 0.4 mm |
| Response delay | minimum: 60 ms factory setting: 330 ms |
| Time delay before availability | t v | ≤ 1600 ms |
| Transducer frequency | approx. 175 kHz |
| Environment and package | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Height | 40 mm |
| Height 40 mm Width 40 mm Length 40 mm | Height | 40 mm | Width | 40 mm | Length | 40 mm |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Temperature influence | ≤ 1.5 % of full-scale value |
| Other | |
| 0 Level | 0 ... 1 V |
| 1 Level | 4 V ... U B |
| Adjustment range | 80 ... 2000 mm |
| Beam width | wide |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Common mode operation | ≤ 30 Hz |
| Common mode operation ≤ 30 Hz Multiplex operation ≤ 33 Hz / n , n = number of sensors , n ≤ 10 (factory setting: n = 5 ) | Common mode operation | ≤ 30 Hz | Multiplex operation | ≤ 33 Hz / n , n = number of sensors , n ≤ 10 (factory setting: n = 5 ) |
| Connection type | Connector plug M12 x 1 , 5-pin |
| Dead band | 0 ... 60 mm |
| Degree of protection | IP67 |
| Deviation of the characteristic curve | ≤ 0.2 % of full-scale value |
| Evaluation procedure | low-pass behavior |
| Housing | PA-GF35 |
| Housing PA-GF35 Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam | Housing | PA-GF35 | Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Input/output type | 1 synchronization connection, bidirectional |
| Input type | 1 program input |
| Interface type | Serial interface (programming adapter required) 9600 BPS, no parity, 8 data bits, 1 stop bit |
| LED green | Operating display |
| LED red | error |
| LED yellow | object in evaluation range |
| Length | 40 mm |
| Level (evaluation limit 1) | 0 ... 1 V |
| Level (evaluation limit 2) | 4 V ... U B |
| Mass | 115 g |
| Multiplex operation | ≤ 33 Hz / n , n = number of sensors , n ≤ 10 (factory setting: n = 5 ) |
| Output | evaluation limit A1: 80 mm evaluation limit A2: 2000 mm output function: rising ramp |
| Output type | 1 analog output 4 ... 20 mA |
| Pulse interval | ≥ 33 ms (level 0) |
| Pulse length | 0.5 ... 300 ms (level 1) |
| Sensing range | 60 ... 2000 mm |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 | Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standard target plate | 100 mm x 100 mm |
| Supplementary information | Switch settings of the external programming adapter: "output load": pull-down "output logic": noninv |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| UL approval | cULus Listed, General Purpose |
| Width | 40 mm |
Documents
No documents are linked to this part yet.