All alternatives

View full report

Technical parameters

Power
Connection digital valve, terminals SV Output type (1) SPST, powered contacts from supply 5.0 A at 250 VAC or 30 VDC Inrush current 5 AConnection | digital valve, terminals SV | Output type | (1) SPST, powered contacts from supply 5.0 A at 250 VAC or 30 VDC | Inrush current | 5 A
Connection K2, terminals: K2 (NO, C, NC) Output type alarm, (1) SPDT Inrush current 3 A Contact loading 3 A at 250 V AC , 30 V DC resistive load, 3 A at 30 V DCConnection | K2, terminals: K2 (NO, C, NC) | Output type | alarm, (1) SPDT | Inrush current | 3 A | Contact loading | 3 A at 250 V AC , 30 V DC resistive load, 3 A at 30 V DC
Inrush current6 A
Power consumption100 ... 240 V AC - 2.3 VA (without digital valve) 20 ... 30 V DC - 2.5 W (without digital valve)
Protective gas supplyinstrument grade air or inert gas
Rated voltageU r | 100 ... 240 V AC, 0.05 A, 50 ... 60 Hz 20 ... 30 V DC, 0.2 A
Environment and package
Ambient temperature-20 ... 40 °C (-4 ... 104 °F) at T6 -20 ... 60 °C (-4 ... 140 °F) at T4
Connection Pt100, 2-wire-connection Input type temperature input Input accuracy: 2.5% of the measurement value + PT100 errorConnection | Pt100, 2-wire-connection | Input type | temperature input Input accuracy: 2.5% of the measurement value + PT100 error
Dimensions165 x 124 x 90 mm (6.5 x 4.9 x 3.5 in)
Directive 2011/65/EU (RoHS)EN IEC 63000:2018
Directive 2011/65/EU (RoHS) EN IEC 63000:2018Directive 2011/65/EU (RoHS) | EN IEC 63000:2018
Height203 mm
Height 203 mm Width 165 mm Depth 105 mmHeight | 203 mm | Width | 165 mm | Depth | 105 mm
Other
Cable glandCable size M12 diameter 3 - 6.5 mm M20 diameter 10 - 12 mm RTD/Bypass : (3) M12x1.5 K1, K2, SV : 'P_C' (3) M20x1.5
CertificateDEMKO 14 ATEX 1282X
ConnectionPt100, 2-wire-connection
Connection passive contact (switch) Input type mechanical contactConnection | passive contact (switch) | Input type | mechanical contact
Connection typeHigh pressure port: 1/8" NPTF Low pressure port: 1/8" NPTF
Contact loading6 A at 250 V AC , 30 V DC resistive load, 6 A at 30 V DC
cULusUL File E184741 Class I, Division 2, Groups A, B, C, D T4 (-20 °C ≤ Ta ≤ 60 °C) Class II, Division 2, Groups F, G, T4 (-20 °C ≤ Ta ≤ 60 °C) Class I, Division 2, Groups A, B, C, D T6 (-20 °C ≤ Ta ≤ 40 °C) Class II, Division 2, Groups F, G T6 (-20 °C ≤ Ta ≤ 40 °C)
Degree of protectionEN 60529
Depth105 mm
Directive 2014/30/EUEN 61326-1:2013
Directive 2014/30/EU EN 61326-1:2013Directive 2014/30/EU | EN 61326-1:2013
Directive 2014/34/EUEN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-15:2019 , EN 60079-2:2014 , EN 60079-7:2015+A1:2018 , EN 60079-31:2014
Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-15:2019 , EN 60079-2:2014 , EN 60079-7:2015+A1:2018 , EN 60079-31:2014Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-11:2012 , EN 60079-15:2019 , EN 60079-2:2014 , EN 60079-7:2015+A1:2018 , EN 60079-31:2014
Hazardous environmentgas or dust
IECEx approvalIECEx UL 14.0019X Ex ic ec nC [ic Gc] [pzc Gc] IIC T4 Gc (-20 °C ≤ Ta ≤ 60 °C) Ex ic ec nC [ic Gc] [pzc Gc] IIC T6 Gc (-20 °C ≤ Ta ≤ 40 °C) Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (external version) Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (external version) Ex ic tc [ic Dc] [pzc Dc] IIIC T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (internal version) Ex ic tc [ic Dc] [pzc Dc] IIIC T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (internal version)
Impact resistance30 g, 11 ms, all axes
Input ITemperature, up to 2 RTDs per unit
Input II1 Bypass
Input typetemperature input Input accuracy: 2.5% of the measurement value + PT100 error
LED indicationMembrane Pad K1: Green - Contact K1 is energized K2: Amber - Contact K2 is energized SV/encl press.: Blue for safe pressure, Amber for valve on Bypass: Amber when bypass is active PT100 error: Red when fault in PT100 sensor
MarkingII 3 (3) G Ex ic ec nC [ic Gc] [pzc Gc] IIC T4 Gc (-20 °C ≤ Ta ≤ 60 °C) [exsign] II 3 (3) G Ex ic ec nC [ic Gc] [pzc Gc] IIC T6 Gc (-20 °C ≤ Ta ≤ 40 °C) [exsign] II 3 (3) D Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (external version) [exsign] II 3 (3) D Ex ic tc [ic IIIC Dc] [pzc Dc] IIIB T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (external version) [exsign] II 3 (3) D Ex ic tc [ic Dc] [pzc Dc] IIIC T80 °C Dc (-20 °C ≤ Ta ≤ 60 °C) (internal version) [exsign] II 3 (3) D Ex ic tc [ic Dc] [pzc Dc] IIIC T60 °C Dc (-20 °C ≤ Ta ≤ 40 °C) (internal version)
Massapprox. 2.7 kg (6 lb)
MaterialHousing : 316 stainless steel Cable Gland : 316 stainless steel or Nickel Plated Brass Pressure Ports : 316 stainless steel Membrane Pad : Autotex F200XE O-ring: EPDM
Number of volume exchanges4 ... 19
Operating modefully automatic (FA)
Output typeenclosure power, (1) SPST
Relative humidity5 ... 95 %, non-condensing
Safe pressure- gas 0.7 mbar (0.3 in w.c.) - dust 1.6 mbar (0.65 in w.c.)
Series5500
Shock resistanceEN 60068-2
Supplementary informationType Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
SystemType Z Purge ; Ex pzc Purge
Vibration resistance5 ... 100 Hz , 1 g, 12 m/s 2 , all axes
Width165 mm

Documents

No documents are linked to this part yet.