All alternatives

View full report

Technical parameters

Power
Power supply5V+-5%
AC and DC characteristics
Max. scanning frequency50.00 kHz
Environment and package
Accuracy grade± 5.0 µm
Other
Electrical connectionFlange socket, male, 14-pin
Fastening typeEnd block + mounting spar
Fault detection signalfor disturbance Ua1/Ua2 high-impedance
Further reference marksnone
Grating period20.000 µm
ID number605379-9A
Measuring length1140 mm
Output signalSquare-wave signals, TTL levels with 5-fold interpolation
Reference mark positionML/2 - in the middle of the measuring length
Reference pulse width270°
Special characteristics, linear encodernone
Total lengthML+138 mm

Documents