All alternatives

View full report

Technical parameters

Power
Voltage U i24 V
Voltage U i 24 VVoltage U i | 24 V
Environment and package
Ambient temperaturesee table 1
Design / MountingOutside installation
Mountingwall mounting
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Busup to 2.5 mm 2
Bus see Statement of Conformity Input see EC-Type Examination CertificateBus | see Statement of Conformity | Input | see EC-Type Examination Certificate
Bus up to 2.5 mm 2 Inputs up to 2.5 mm 2Bus | up to 2.5 mm 2 | Inputs | up to 2.5 mm 2
Cable diametersee table 2
Cable glandsensor inputs M16, fieldbus M20
CertificatePTB 03 ATEX 2238 X
Connection typeplug-in terminals , spring terminal and screw terminal
Control drawing16-473FM-12A
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Degree of protectionIEC 60529
Directive 2014/30/EUEN 61326-1:2013
Directive 2014/30/EU EN 61326-1:2013Directive 2014/30/EU | EN 61326-1:2013
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010
Electromagnetic compatibilityNE 21:2011
Electronic componentTemperature Multi-Input Device RD0-TI-Ex8.PA* For technical data on installed electronic component see datasheet.
EU-type examination certificatePTB 03 ATEX 2237
Fieldbus standardIEC 61158-2
Fieldbus typePROFIBUS PA
FM certificateFM18US0054X , FM18CA0027X
FM certificate FM18US0054X , FM18CA0027X Control drawing 16-473FM-12AFM certificate | FM18US0054X , FM18CA0027X | Control drawing | 16-473FM-12A
Galvanic isolationEN 60079-11
Housing materialAluminum
IECEx certificateIECEx PTB 05.0001 IECEx PTB 05.0002X
IECEx certificate IECEx PTB 05.0001 IECEx PTB 05.0002X IECEx marking Ex ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 GcIECEx certificate | IECEx PTB 05.0001 IECEx PTB 05.0002X | IECEx marking | Ex ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc
IECEx markingEx ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc
Inputsee EC-Type Examination Certificate
Inputsup to 2.5 mm 2
Installation in hazardous areaZone 1 / Div. 1
MarkingII 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc
Marking II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 GcMarking | II 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc
Marking II 3 G Ex nA IIC T4 GcMarking | II 3 G Ex nA IIC T4 Gc
Mass1800 g
Number8
Relative humidity≤ 95 % non-condensing
Shock resistanceEN 60068-2-27
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Vibration resistanceEN 60068-2-6

Documents

No documents are linked to this part yet.