View full reportTechnical parameters
| Power | |
|---|---|
| Current | 0 ... 25 mA short-circuit protected |
| Number of channels | 1 |
| Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Output/power supply, internal bus safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V | Output/power supply, internal bus | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Power | P o | 575 mW (linear characteristic) |
| Power consumption | 0.95 W |
| Power dissipation | 0.8 W |
| Rated voltage | U r | 12 V DC , only in connection with the power supplies LB9*** |
| Voltage | U o | 27 V |
| Voltage U o 27 V Current I o 87 mA Power P o 575 mW (linear characteristic) | Voltage | U o | 27 V | Current | I o | 87 mA | Power | P o | 575 mW (linear characteristic) |
| Environment and package | |
| After calibration 0.1 % of the signal range at 20 °C (68 °F) Influence of ambient temperature 0.1 %/10 K of the signal range | After calibration | 0.1 % of the signal range at 20 °C (68 °F) | Influence of ambient temperature | 0.1 %/10 K of the signal range |
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Height | 100 mm |
| Height 100 mm Width 16 mm Depth 102 mm | Height | 100 mm | Width | 16 mm | Depth | 102 mm |
| Influence of ambient temperature | 0.1 %/10 K of the signal range |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Other | |
| After calibration | 0.1 % of the signal range at 20 °C (68 °F) |
| Altitude | max. 2000 m |
| ATEX approval | BVS 11 ATEX E 116X |
| Coding | optional mechanical coding via front socket |
| Connection | backplane bus |
| Damaging gas | EN 60068-2-42:2003 |
| Degree of protection | IEC 60529:2000 |
| Depth | 102 mm |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Directive 2014/30/EU EN 61326-1:2013 | Directive 2014/30/EU | EN 61326-1:2013 |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN IEC 60079-11:2024 EN 60079-15:2010 |
| Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 EN IEC 60079-11:2024 EN 60079-15:2010 | Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN IEC 60079-11:2024 EN 60079-15:2010 |
| Electromagnetic compatibility | NE 21:2007 |
| Environmental test | EN 60068-2-14:2009 |
| EU-type examination certificate | BVS 11 ATEX E 116 X |
| Field device | Proportional Valve |
| Field device [2] | I/P converters |
| Field device [3] | on-site display |
| Field device Proportional Valve Field device [2] I/P converters Field device [3] on-site display | Field device | Proportional Valve | Field device [2] | I/P converters | Field device [3] | on-site display |
| HART communication | yes |
| HART secondary variable | MODBUS: yes; all other bus systems: no |
| IECEx certificate | IECEx BVS 11.0068X |
| IECEx certificate IECEx BVS 11.0068X IECEx marking Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I | IECEx certificate | IECEx BVS 11.0068X | IECEx marking | Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I |
| IECEx marking | Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I |
| Interface | manufacturer-specific bus to standard com unit |
| LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1) red: line fault (lead breakage or short circuit) |
| Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
| Load | 750 Ω max. |
| Marking | II 3(1) G Ex nA [ia Ga] IIC T4 Gc [exsign] I (M1) [Ex ia Ma] I [exsign] II (1) D [Ex ia Da] IIIC |
| Marking II 3(1) G Ex nA [ia Ga] IIC T4 Gc [exsign] I (M1) [Ex ia Ma] I [exsign] II (1) D [Ex ia Da] IIIC | Marking | II 3(1) G Ex nA [ia Ga] IIC T4 Gc [exsign] I (M1) [Ex ia Ma] I [exsign] II (1) D [Ex ia Da] IIIC |
| Mass | approx. 90 g |
| Occupied slots | 1 |
| Open-circuit | deviation of preset output value > 0.5 mA |
| Refresh time | 100 ms |
| Relative humidity | EN 60068-2-78:2001 |
| Safety Integrity Level (SIL) | SIL 2 |
| Shock resistance | EN 60068-2-27:2009 |
| Short-circuit | No |
| Short-circuit No Open-circuit deviation of preset output value > 0.5 mA | Short-circuit | No | Open-circuit | deviation of preset output value > 0.5 mA |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. |
| UL approval | E106378 |
| Vibration resistance | EN 60068-2-6:2008 |
| Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
| Width | 16 mm |