Power
Inductive overvoltage protectionyes
No-load supply currentI 0 | ≤ 7 mA
Off-state currentI r | 0 ... 0.5 mA typ. 0.1 µA at 25 °C
Operating currentI L | 0 ... 200 mA
Operating voltageU B | 5 ... 60 V
Rated insulation voltageU BIS | 60 V
Voltage dropU d | ≤ 2 V
AC and DC characteristics
Switching frequencyf | 0 ... 2500 Hz
Time delay before availabilityt v | ≤ 200 ms
Environment and package
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Actuating elementmild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm
Assured operating distances a | 0 ... 3.24 mm
Bending radius> 6 x cable diameter
Cable diameter6 mm ± 0.2 mm
CCC approvalCertified by China Compulsory Certification (CCC)
Colorblack
Connection typecable
Core cross section0.75 mm 2
CSA approvalcCSAus Listed, General Purpose
Degree of protectionIP68 / IP69K
Diagnostic Coverage (DC)0 %
Diameter12 mm
E1 Type approval10R-06
Housing materialPBT
HysteresisH | typ. 5 %
Installationflush
LengthL | 2 m
Length 50 mm Diameter 12 mmLength | 50 mm | Diameter | 12 mm
Mass110 g
MaterialPUR
Mission Time (T M )20 a
MTTF d1006 a
Number of cores3
Output polarityDC
Output typePNP
Rated operating distances n | 4 mm
Reduction factor r 3040.7
Reduction factor r Al0.35
Reduction factor r Brass0.4
Reduction factor r Cu0.25
Reverse polarity protectionreverse polarity protected
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Surge suppressionyes
Switching functionNormally closed (NC)
Switching state indicatorLED, yellow
UL approvalcULus Listed Circuitry: Class 2 Power Source Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA
Wire end ferrulesyes