All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | ≤ 15 mA
Off-state currentI r | 0 ... 0.5 mA typ. 0.1 µA at 25 °C
Operating currentI L | 0 ... 100 mA
Operating voltageU B | 4.75 ... 30 V DC
Voltage dropU d | ≤ 2 V
AC and DC characteristics
Switching frequencyf | 0 ... 1000 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Height10 mm
Height 10 mm Width 27 mm Length 6 mmHeight | 10 mm | Width | 27 mm | Length | 6 mm
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Assured operating distances a | 0 ... 1.62 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Connection typecable PVC , 2 m 130 mm stripped
Core cross section0.14 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Housing materialRyton R4
HysteresisH | typ. 5 %
Installationflush
Length6 mm
Mission Time (T M )20 a
MTTF d1680 a
Output polarityDC
Output typePNP
Rated operating distances n | 2 mm
Reduction factor r 3040.7
Reduction factor r Al0.2
Reduction factor r Cu0.15
Reverse polarity protectionreverse polarity protected
Sensing faceRyton R4
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functioncomplementary
Switching state indicatorLED, yellow
UL approvalcULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA
Width27 mm

Documents

No documents are linked to this part yet.