Power
No-load supply currentI 0 | max. 30 mA
Operating voltageU B | 10 ... 30 V DC , class 2
Switching currentmax. 100 mA
Switching voltagemax. 30 V DC
Voltage dropU d | ≤ 2.5 V DC
AC and DC characteristics
Ripplemax. 10 %
Switching frequencyf | 1000 Hz
Environment and package
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Height56.5 mm
Height 56.5 mm Width 31 mm Depth 13.6 mmHeight | 56.5 mm | Width | 31 mm | Depth | 13.6 mm
Storage temperature-40 ... 75 °C (-40 ... 167 °F)
Other
Ambient light limit50000 Lux
CCC approvalCCC approval / marking not required for products rated ≤36 V
Connection4-pin, M12 x 1 connector
Connectormetal
Control elementssensitivity adjustment (receiver)
Control inputHigh power mode activation with +UB (emitter)
Degree of protectionIP67
Depth13.6 mm
Diagnostic Coverage (DC)0 %
Diameter of the light spotapprox. 500 mm at detection range 16 m
Effective detection range0 ... 16 m
EMC Directive 2004/108/ECEN 60947-5-2:2007
EMC Directive 2004/108/EC EN 60947-5-2:2007EMC Directive 2004/108/EC | EN 60947-5-2:2007
EmitterM41-F2/76a/92
Function indicatorReceiver: LED yellow, lights up when light beam is free, flashes when falling short of the operating reserve ; OFF when light beam is interrupted
HousingAluminum , Delta-Seal coated
Housing Aluminum , Delta-Seal coated Optical face glass pane Connector metalHousing | Aluminum , Delta-Seal coated | Optical face | glass pane | Connector | metal
Light sourcenormal mode: LED High power mode: LED+IRED
Light typenormal mode: modulated visible red light High power mode: Red and infrared, modulated light
Mass50 g (device)
Mission Time (T M )20 a
MTTF d844 a
Opening angleapprox. 1.5 °
Operation indicatorLED green: power on
Optical facefrontal
Product standardEN 60947-5-2:2007 IEC 60947-5-2:2007
Product standard EN 60947-5-2:2007 IEC 60947-5-2:2007 Standards UL 508Product standard | EN 60947-5-2:2007 IEC 60947-5-2:2007 | Standards | UL 508
ReceiverMV41-F2/82b/92/103
Response time0.5 ms
Signal output1 PNP, short-circuit protected, reverse polarity protected, open collector
Stability alarm output1 PNP, inactive when falling short of the operating reserve
StandardsUL 508
Switching typedark-on
Test inputemitter deactivation at +U B (emitter)
Threshold detection rangenormal mode: 25 m High power mode: 35 m (Control input at UB+)
UL approvalcULus Listed, Class 2 Power Source, Type 1 enclosure
Width31 mm

Documents