All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Protective gas supply | instrument grade air or inert gas |
| Environment and package | |
| Ambient temperature | -29 ... 49 °C (-20.2 ... 120.2 °F) |
| Other | |
| Capacity and filtration | 1.5 oz @ 20 µ |
| Connection type | System supply port: 1/4" FTP Enclosure supply fitting: 1/4" tube fitting Enclosure reference fitting: 1/4" tube fitting |
| cULus | Class I, Division 2, Groups A, B, C, D |
| cULus Class I, Division 2, Groups A, B, C, D | cULus | Class I, Division 2, Groups A, B, C, D |
| Exchange flow rate | 4 SCFM / 240 SCFH (With regulator set to 60 psi min. during exchange) |
| Exchange pressure | 3" - 5" |
| Exchange time | 1 min / ft 3 |
| Hazardous environment | gas |
| Mass | 4.5 kg (10 lb) |
| Material | Filter regulator body: zinc w/enamel finish Regulator handle & bowl: polycarbonate Enclosure pressure gauge: alum. w/enamel finish Rapid Exchange ® gauge: poly case and brass tube Tube fittings & valves: 316 ss forged body Tubing: 316 ss 1/4" .035 welded System nameplate: silk-screened Lexan ® & 6061 aluminum Fastener hardware: alum. & stainless steel Mounting plate: 6061 Aluminum Enclosure warning nameplate: silk-screened stainless steel |
| Pressure requirement | 80 - 120 psi |
| Safe pressure | Setpoint: 0.25" (6.35 mm) Flow rate: 0.1 - 3.5 SCFH (2.8 - 99 l /hr) |
| Series | 1012 |
| System | Type Y Purge , Type Z Purge |
Documents
No documents are linked to this part yet.