All alternatives

View full report

Technical parameters

Power
Output type Switch contacts Contact loading 120/220 VAC; 24 VDC @ 10 A; 125 VDC @ 50 mA power requirements: 24 / 120 / 240 VDC @ 3 / 4 / 11 wattsOutput type | Switch contacts | Contact loading | 120/220 VAC; 24 VDC @ 10 A; 125 VDC @ 50 mA power requirements: 24 / 120 / 240 VDC @ 3 / 4 / 11 watts
Protective gas supplyinstrument grade air or inert gas
Environment and package
Ambient temperature-29 ... 49 °C (-20.2 ... 120.2 °F)
Other
Capacity and filtration8.5 oz @ 40 µ
ConnectionTerminal blocks
Connection typeSystem supply port: 1/2" FPT Enclosure supply fitting: 1/2" tube fitting Enclosure reference fitting: 1/4" tube Switch conduit port size: 1/2" FPT
Contact loading120 VAC @ 15 A
cULusType Y LPS: Class I, Division 1, Groups A, B, C, D WPS: Class I, Division 1, Groups C, D WPSA: Class I, Division 1, Groups A, B, C, D Type Z LPS: Class I, Division 2, Groups A, B, C, D WPS: Class I, Division 2, Groups C, D WPSA: Class I, Division 2, Groups A, B, C, D
Exchange flow rate30 SCFM / 1800 SCFH (With regulator set to 80 psi min during exchange)
Exchange pressure3" - 5"
Exchange time1 min / 7.5 ft 3
FM approvalType Y LPS: Class I, Division 1, Groups A, B, C, D WPS: Class I, Division 1, Groups C, D WPSA: Class I, Division 1, Groups A, B, C, D Type Z LPS: Class I, Division 2, Groups A, B, C, D WPS: Class I, Division 2, Groups C, D WPSA: Class I, Division 2, Groups A, B, C, D
Hazardous environmentgas
Mass1004-LPS-* 6.8 kg (15 lb) 1004-WPS* 10.4 kg (23 lb)
MaterialFilter regulator body: zinc w/enamel finish Regulator handle & bowl: polycarbonate Enclosure pressure gauge: alum. w/enamel finish Rapid Exchange ® gauge: poly case and brass tube Tube fittings & valves: 316 ss forged body Tubing: 316 ss 1/4" & 1/2" .035 welded System nameplate: silk screened Lexan ® & ss Fastener hardware: alum. & stainless steel Mounting plate: 316 14 ga #3 brush ss EXP pressure switch body: anodized cast aluminum Enclosure warning nameplate: silk screened stainless steel
Output I-WPS-
Output II-WPSA-
Output typeSwitch contacts
Output type Switch contacts Contact loading 120 VAC @ 15 AOutput type | Switch contacts | Contact loading | 120 VAC @ 15 A
Pressure requirement80 - 120 psi
Safe pressureSetpoint: 0.25" (6.35 mm) Flow rate: 0.1 - 3.5 SCFH (2.8 - 99 l /hr)
Series1004
SystemType Y Purge , Type Z Purge

Documents

No documents are linked to this part yet.