All alternatives

View full report

Technical parameters

Power
Lowest operating currentI m | 0 mA
No-load supply currentI 0 | ≤ 15 mA
Off-state currentI r | 0 ... 0.5 mA typ. 0.01 mA
Off-state current T U =40 °C, switching element off≤ 100 µA
Off-state current T U =40 °C, switching element off ≤ 100 µAOff-state current T U =40 °C, switching element off | ≤ 100 µA
Operating currentI L | 0 ... 400 mA
Operating voltageU B | 10 ... 60 V
Voltage dropU d | ≤ 3 V
Voltage drop I L = 100 mA, switching element onU d | 1.5 ... 2.5 V typ. 1.9 V
Voltage drop I L = 100 mA, switching element on U d 1.5 ... 2.5 V typ. 1.9 VVoltage drop I L = 100 mA, switching element on | U d | 1.5 ... 2.5 V typ. 1.9 V
AC and DC characteristics
Switching frequencyf | 0 ... 500 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
A0 mm
A 0 mm B 0 mm C 15 mmA | 0 mm | B | 0 mm | C | 15 mm
Actual operating distances r | 4.5 ... 5.5 mm typ. 5 mm
Assured operating distances a | 0 ... 4.05 mm
B0 mm
Bending radius> 10 x cable diameter
C15 mm
Cable diameter6.2 mm ± 0.2 mm
CCC approvalCertified by China Compulsory Certification (CCC)
Colorblack
Connection typecable
Core cross section0.5 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Diameter18 mm
Housing materialPBT
HysteresisH | typ. 8 %
Installationflush
LengthL | 10 m
Length 50 mm Diameter 18 mmLength | 50 mm | Diameter | 18 mm
MaterialPVC
Mission Time (T M )20 a
MTTF d1140 a
Number of cores4
Output polarityDC
Output typePNP
Rated operating distances n | 5 mm
Reduction factor r 3040.7
Reduction factor r Al0.4
Reduction factor r Cu0.35
Reverse polarity protectionreverse polarity protected
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functioncomplementary
Switching state indicatorall direction LED, yellow
UL approvalcULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 400 mA
Wire end ferrulesyes

Documents

No documents are linked to this part yet.