All alternatives

View full report

Technical parameters

Power
Operating voltageU B | 10 ... 30 V DC , ripple 10 % SS
Power consumptionP 0 | ≤ 900 mW
AC and DC characteristics
Load impedancecurrent output: ≤ 500 Ohm voltage output: ≥ 1000 Ohm
Repeat accuracy≤ 0.1 % of full-scale value
Resolutionevaluation range [mm]/4000, but ≥ 0.35 mm
Response delay65 ms minimum 195 ms factory setting
Transducer frequencyapprox. 180 kHz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Temperature influence≤ 2 % from full-scale value (with temperature compensation) ≤ 0.2 %/K (without temperature compensation)
Temperature/teach-in connectorTemperature compensation , Evaluation range programming , output function setting
Other
Adjustment range120 ... 2000 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Common mode operationmax. 30 Hz
Common mode operation max. 30 Hz Multiplex operation ≤ 30/n Hz, n = number of sensorsCommon mode operation | max. 30 Hz | Multiplex operation | ≤ 30/n Hz, n = number of sensors
Connection typeCable connector , M12 x 1 , 5-pin , 4-wire
Control drawing116-0168
Dead band0 ... 80 mm
Degree of protectionIP65
Deviation of the characteristic curve≤ 0.2 % of full-scale value
Diameter35 mm
Hazardous LocationE199034
Housing1.4303 stainless steel plastic parts PBT
Housing 1.4303 stainless steel plastic parts PBT Transducer epoxy resin/hollow glass sphere mixture; polyurethane foamHousing | 1.4303 stainless steel plastic parts PBT | Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam
Interface typeRS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
LED greensolid: Power-on flashing: Standby mode or program function object detected
LED redsolid: temperature/program plug not connected flashing: fault or program function object not detected
LED yellow 1solid: object in evaluation range flashing: program function
LED yellow 2solid: object in detection range flashing: program function
Length172 mm
Length 172 mm Diameter 35 mmLength | 172 mm | Diameter | 35 mm
Multiplex operation≤ 30/n Hz, n = number of sensors
NoteIndividual components: UC-2000-30GM-IUR2-V15; V1-G-2M-PVC; M-106 impact adapter; ADAPT-ALUM*-M30X1/2" NPT/HB****
Ordinary LocationE87056
Ordinary Location 1007121Ordinary Location | 1007121
Ordinary Location E87056 Hazardous Location E199034 Control drawing 116-0168Ordinary Location | E87056 | Hazardous Location | E199034 | Control drawing | 116-0168
Output type1 current output 4 ... 20 mA 1 voltage output 0 ... 10 V
Sensing range80 ... 2000 mm
StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003
Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003
Standard target plate100 mm x 100 mm
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam

Documents

No documents are linked to this part yet.