All alternatives

View full report

Technical parameters

Power
1) Voltage Rating300 V RMS
AC and DC characteristics
4) Characteristic Impedance83 Ω
Environment and package
1) Temperature Range-50 to 125°C
Other
125°C / 300 V RMS125°C / 300 V RMS
(1) Color CodeAlpha Wire Color Code E
1) Component 12 X 1 COND
2) Bend Radius10X Cable Diameter
2) Cable Assembly2 Components Cabled
2) California Proposition 65This product may contain substances known to the State of California to cause Cancer or Reproductive Harm, but is exempt from labeling based on the Consent Judgement. See the Alpha Wire website for more information.
2) Capacitance19.4 pF/ft @1 kHz, Nominal Conductor to Conductor
3) Ground Capacitance35 pF/ft @1 kHz, Nominal
3) OtherPENNSYLVANIA BUREAU OF MINE SAFETY APPROVED
3) Pull Tension12.5 Lbs, Maximum
3) ShieldA/P/A Tape, 25% Overlap, Min.
4) CEEU Low Voltage Directive 2014/35/EU
4) Sunlight ResistanceYes
5) Inductance0.22 μH/ft, Nominal
6) Conductor DCR25 Ω/1000ft @20°C, Nominal
7) OA Shield DCR7.2 Ω/1000ft @20°C, Nominal
a) Color(s)Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
a) Drain Wire24 (7/32) AWG Tinned Copper
a) Twists8.0 Twists/foot (min)
AWM/STYLE 20237AWM/STYLE 21918
AWM/STYLE 21918125°C / 300 V RMS
b) BraidTinned Copper,70% Coverage, Nom.
b) OrientationComponents to be arranged from INSIDE LAYER to OUTSIDE LAYER
b) Ripcord1 End 810 Denier Nylon
c) Core WrapNonwoven Polyester Tape, 25% Overlap, Min.
ColorBLACK
Cond1
c) PrintALPHA WIRE-* P/N 45112 XTRAGUARD(R) 4 RU AWM 20237/21918 125C 300V SUN RES OR CRU AWM I/II A/B 125C 300 VOLTS FT1 P-07-KA140023-MSHA CE ROHS (SEQ FOOTAGE) * = Factory Code
Electrical Properties(For Engineering purposes only)
PackagingFlange x Traverse x Barrel (inches)

Documents