All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | ≤ 12 mA
Off-state currentI r | 0 ... 0.1 mA typ. 0.1 µA at 25 °C
Operating currentI L | 0 ... 100 mA
Operating voltageU B | 10 ... 30 V
Voltage dropU d | ≤ 3 V
AC and DC characteristics
Switching frequencyf | 0 ... 3000 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Other
Assured operating distances a | 0 ... 0.648 mm
Bending radius> 12 x cable diameter
Cable diameter3 mm - 0.2 mm
Cable diameter 3 mm - 0.2 mm Bending radius > 12 x cable diameter Material PVC Color grey Number of cores 3 Core cross section 0.14 mm 2 Length L 0.3 mCable diameter | 3 mm - 0.2 mm | Bending radius | > 12 x cable diameter | Material | PVC | Color | grey | Number of cores | 3 | Core cross section | 0.14 mm 2 | Length | L | 0.3 m
CCC approvalCCC approval / marking not required for products rated ≤36 V
Colorgrey
Connection typefixed cable with plug
Core cross section0.14 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Diameter5 mm
Housing materialStainless steel 1.4305 / AISI 303
HysteresisH | 5 ... 20 %
Installationflush
LengthL | 0.3 m
Length 25 mm Diameter 5 mmLength | 25 mm | Diameter | 5 mm
MaterialPVC
Mission Time (T M )20 a
MTTF d2140 a
Number of cores3
Number of pins3
Output polarityDC
Output typeNPN
Rated operating distances n | 0.8 mm
Reduction factor r 3040.85
Reduction factor r Al0.45
Reduction factor r Cu0.4
Reverse polarity protectionreverse polarity protected
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorLED, yellow
ThreadingM8 x 1
Threading M8 x 1 Number of pins 3Threading | M8 x 1 | Number of pins | 3
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA

Documents

No documents are linked to this part yet.