All alternatives

View full report

Technical parameters

Power
Operating voltageU B | 90 ... 140 V AC 47 ... 63 Hz
Power consumptionP 0 | ≤ 75 mA
Rated operating currentI e | 700 mA
Voltage dropU d | ≤ 1.5 V AC
AC and DC characteristics
Repeat accuracy≤ 5 mm
Response delay≤ 45 ms
Switching frequencyf | 15 Hz
Transducer frequency400 kHz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Temperature influence< 2 % of far switch point
Other
Connection type5-pin , V95 connector
Dead band0 ... 70 mm
Degree of protectionIP65
Diameter30 mm
Diameter 30 mmDiameter | 30 mm
Housingnickel plated brass; plastic components: PBT
Housing nickel plated brass; plastic components: PBT Transducer epoxy resin/hollow glass sphere mixture; polyurethane foamHousing | nickel plated brass; plastic components: PBT | Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam
LED greenpower
LED redOutput
Output typeThyristor , 1 NO
Range hysteresisH | approx. 15 mm
Sensing range70 ... 500 mm
StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019
Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019
Standard target plate100 mm x 100 mm
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam
UL approvalcULus Listed, General Purpose

Documents

No documents are linked to this part yet.