All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | ≤ 30 mA
Operating voltageU B | 10 ... 30 V DC , ripple 10 % SS
Rated operating currentI e | 15 mA , short-circuit/overload protected
AC and DC characteristics
Impedance10 kOhm internal connected to +U B
Transducer frequencyapprox. 180 kHz
Environment and package
Ambient temperature-25 ... 85 °C (-13 ... 185 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Temperature influencethe echo propagation time: 0.17 % / K
Other
Adjustment range120 ... 2000 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Connection2 m PVC cable 0.34 mm 2
Dead band0 ... 80 mm 1)
Degree of protectionIP67
Diameter30 mm
Housingnickel plated brass; plastic components: PBT
Housing nickel plated brass; plastic components: PBT Transducer epoxy resin/hollow glass sphere mixture; polyurethane foamHousing | nickel plated brass; plastic components: PBT | Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam
Input type1 pulse input for transmitter pulse (clock) 0-level (active): < 5 V (U B > 15 V) 1-level (inactive): > 10 V ... +U B (U B > 15 V) 0-level (active): < 1/3 U B (10 V < U B < 15 V) 1-level (inactive): > 2/3 U B ... +U B (10 V < U B < 15 V)
Length80 mm
Length 80 mm Diameter 30 mmLength | 80 mm | Diameter | 30 mm
Mass195 g
Output type1 pulse output for echo run time, short-circuit proof open collector PNP with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): ≥ (+U B -2 V)
Pause length≥ 50 x pulse length
Pulse length20 ... 300 µs (typ. 200 µs) 2)
Sensing range80 ... 2000 mm
StandardsEN IEC 60947-5-2:2020 IEC 60947-5-2:2019
Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019
Standard target plate100 mm x 100 mm
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam
UL approvalcULus Listed, General Purpose

Documents

No documents are linked to this part yet.