All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | ≤ 30 mA |
| Operating voltage | U B | 10 ... 30 V DC , ripple 10 % SS |
| Rated operating current | I e | 15 mA , short-circuit/overload protected |
| AC and DC characteristics | |
| Impedance | 10 kOhm internal connected to +U B |
| Transducer frequency | approx. 180 kHz |
| Environment and package | |
| Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Temperature influence | the echo propagation time: 0.17 % / K |
| Other | |
| Adjustment range | 120 ... 2000 mm |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Connection | 2 m PVC cable 0.34 mm 2 |
| Dead band | 0 ... 80 mm 1) |
| Degree of protection | IP67 |
| Diameter | 30 mm |
| Housing | nickel plated brass; plastic components: PBT |
| Housing nickel plated brass; plastic components: PBT Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam | Housing | nickel plated brass; plastic components: PBT | Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Input type | 1 pulse input for transmitter pulse (clock) 0-level (active): < 5 V (U B > 15 V) 1-level (inactive): > 10 V ... +U B (U B > 15 V) 0-level (active): < 1/3 U B (10 V < U B < 15 V) 1-level (inactive): > 2/3 U B ... +U B (10 V < U B < 15 V) |
| Length | 80 mm |
| Length 80 mm Diameter 30 mm | Length | 80 mm | Diameter | 30 mm |
| Mass | 195 g |
| Output type | 1 pulse output for echo run time, short-circuit proof open collector PNP with pulldown resistor = 22 kOhm level 0 (no echo): -U B level 1 (echo detected): ≥ (+U B -2 V) |
| Pause length | ≥ 50 x pulse length |
| Pulse length | 20 ... 300 µs (typ. 200 µs) 2) |
| Sensing range | 80 ... 2000 mm |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
| Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 | Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
| Standard target plate | 100 mm x 100 mm |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| UL approval | cULus Listed, General Purpose |
Documents
No documents are linked to this part yet.