Pepperl+Fuchs, Inc.Germany
42519
ActiveLCD batch controller with 2 relay outputs and 90 ... 260 V<sub>AC</sub> supply voltage
All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Low Voltage Directive 2006/95/EC | EN 61010-1:2001; protection class: 2 |
| Low Voltage Directive 2006/95/EC EN 61010-1:2001; protection class: 2 EMC Directive 2004/108/EC EN 61000-6-2:2005, EN 50295:1999 | Low Voltage Directive 2006/95/EC | EN 61010-1:2001; protection class: 2 | EMC Directive 2004/108/EC | EN 61000-6-2:2005, EN 50295:1999 |
| Operating voltage | U B | 90 ... 260 V AC |
| Power consumption | P 0 | max. 8 VA |
| Sensor supply | 20.4 ... 27.6 V DC, max. 80 mA |
| Switching current | max. 3 A AC/DC, min. 30 mA DC, |
| Switching power | max. 750 VA / 90 W |
| Switching voltage | max. 250 V AC / 110 V DC |
| Switching voltage max. 250 V AC / 110 V DC Switching current max. 3 A AC/DC, min. 30 mA DC, Switching power max. 750 VA / 90 W | Switching voltage | max. 250 V AC / 110 V DC | Switching current | max. 3 A AC/DC, min. 30 mA DC, | Switching power | max. 750 VA / 90 W |
| AC and DC characteristics | |
| Counting frequency | 30 Hz / 55 kHz |
| Frequency counter | functions for input A and input B: A, A-B, A+B quad, A/B, (A-B)/A x 100 % |
| Impedance | 5 kOhm |
| Environment and package | |
| Ambient temperature | -20 ... 65 °C (-4 ... 149 °F) |
| Dimensions | 48 mm x 48 mm x 109.8 mm |
| Storage temperature | -25 ... 75 °C (-13 ... 167 °F) |
| Other | |
| Altitude | 0 ... 2000 m |
| Connection | Counter inputs: A and B Control/reset inputs: LOCK, RESET, GATE, MPI |
| Data storage | > 10 years, EEPROM |
| Decimal point | 0 to max 5 fractional digits |
| Degree of protection | IP65 (front) |
| Display value | digit height 9 mm |
| Electrical life | 1 x 10 5 switching cycles at 3 A |
| EMC Directive 2004/108/EC | EN 61000-6-2:2005, EN 50295:1999 |
| Emitted interference | DIN EN 55011:2009, Class B |
| Fusing | 90 … 260 V AC: T 0.1 A |
| High | 12 ... 30 V DC |
| High 12 ... 30 V DC Low 0 ... 4 V DC | High | 12 ... 30 V DC | Low | 0 ... 4 V DC |
| Key interlock | via "high" potential at "LOCK" input |
| Low | 0 ... 4 V DC |
| Mass | approx. 143 g |
| Mechanical life | 2 x 10 7 switching cycles |
| Mechanical life 2 x 10 7 switching cycles Electrical life 1 x 10 5 switching cycles at 3 A | Mechanical life | 2 x 10 7 switching cycles | Electrical life | 1 x 10 5 switching cycles at 3 A |
| Mechanical life 2 x 10 7 switching cycles Electrical life 5 x 10 4 cycles at 3 A | Mechanical life | 2 x 10 7 switching cycles | Electrical life | 5 x 10 4 cycles at 3 A |
| Mech. capacity | EN 60068-2-6:2008 10 … 55 Hz / 1 mm / XYZ 30 min in each direction |
| Minimum pulse duration | Control/reset inputs: 10 ms / 1 ms |
| Output I | Relay with make contact, NC or NO progr. |
| Output II | Relay with changeover contact |
| Pollution degree | 2 |
| Pre-selection | 2-fold |
| Programming | keypad-driven menu |
| Pulse counter | Counting with counting direction (cnt.dir), difference counting (up.dn), up/down counting (quad), Cumulative counting (up.up), up/down counting x 2 (quad 2), up/down counting x 4 (quad 4), additional functions for counter input A and counter input B: A/B, (A-B)/A x 100% |
| Relative humidity | ≤ 93 % at 40 °C (non-condensing) |
| Relay | changeover contact , Make contact |
| Reset | manually or external |
| Response time | Relay: approx. 7 ms Frequency counter: 100/600 ms |
| Scale factor | 0.0001 ... 99.9999 |
| Shock and impact resistance | EN 60068-2-27:1995 100 G / 2 ms / XYZ 3 times in each direction |
| Timer | Time measurement via GATE input (FrErun), counter input A: Start, counter input B: Stop (InpA.InpB.), counter input B: Start/Stop (InpB.InpB.), time measuring via RESET input (auto) |
| Type | 2-line, 2 x 6-digit LC display with leading sign backlighted |
Documents
No documents are linked to this part yet.