| Power | |
|---|---|
| Operating voltage | U B | 10 ... 30 V DC |
| Power consumption | P 0 | 9 VA at 24 V DC |
| AC and DC characteristics | |
| Noise immunity | DIN EN 61000-6-2 |
| Resolution | ± 0.42 mm (1,200 positions/m) |
| Environment and package | |
| Operating temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Other | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Connection type | 5-pin, M12 x 1 connector |
| CSA approval | cCSAus Certified, General Purpose Class 2 power source |
| Data output code | binary code |
| Degree of protection | IP54 |
| Diagnostic Coverage (DC) | 0 % |
| Emitted interference | DIN EN 61000-6-4 |
| Free tolerances to code rail | horizontal: 10 mm ( ± 5 mm ) vertical: 10 mm ( ± 5 mm ) |
| Housing | ABS , Polycarbonate , Polyamide (PA) |
| Housing ABS , Polycarbonate , Polyamide (PA) | Housing | ABS , Polycarbonate , Polyamide (PA) |
| Interface type | RS 485 interface |
| Mass | 500 g |
| Measuring length | max. 327 m |
| Mission Time (T M ) | 10 a |
| MTTF d | 66 a |
| Order information | Mounting plate included with delivery |
| Passage speed | v | ≤ 12.5 m/s |
| Photobiological safety | exempt group according to EN 62471:2008 |
| Protocol | 3 , with Parity (9 Bit/Byte) |
| Relative humidity | 90 % , non-condensing |
| Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
| Termination | with RS 485 termination |
| Transfer rate | 19.2 kBit/s |
| Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |