All alternatives

View full report

Technical parameters

Power
Off-state currentI r | ≤ 800 µA
Operating currentI L | 2 ... 100 mA
Operating voltageU B | 6 ... 30 V DC
Voltage dropU d | ≤ 5.5 V DC
AC and DC characteristics
Switching frequencyf | 0 ... 5 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Other
Actuating elementFerrous targets
Assured operating distances a | 0 ... 1.62 mm
CCC approvalCCC approval / marking not required for products rated ≤36 V
Connection typeConnector plug
Degree of protectionIP67 / IP68 / IP69K - cordset dependent according to cable specification
Diameter12 mm
Housing materialXylan coated - Stainless steel 1.4305 / AISI 303
HysteresisH | 3 ... 15 typ. 5 %
Installationflush
Length75 mm
Length 75 mm Diameter 12 mmLength | 75 mm | Diameter | 12 mm
Mag. Field strength, AC fields250 mT
Mag. Field strength, DC fields250 mT
Mass35 g
Number of pins3
Output polarityDC
Output typeTwo-wire
Rated operating distances n | 2 mm
Reduction factor r 3040.75
Reduction factor r Al0
Reduction factor r Brass0
Reduction factor r Cu0
Reduction factor r St371
Reverse polarity protectionreverse polarity tolerant
Sensing faceXylan coated - Stainless steel 1.4305 / AISI 303
Short-circuit protectionno
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorMultihole-LED, yellow
ThreadingM12 x 1
Threading M12 x 1 Number of pins 3Threading | M12 x 1 | Number of pins | 3
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 30 V DC Output Switching Current: 100 mA

Documents

No documents are linked to this part yet.