All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Off-state current | I r | ≤ 1.3 mA |
| Rated operating current | I e | 8 ... 200 mA AC/DC |
| Rated operating voltage | U e | 20 ... 250 V AC/DC |
| Voltage drop | U d | ≤ 7 V |
| AC and DC characteristics | |
| Switching frequency | f | 30 Hz |
| Environment and package | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Other | |
| Actuating element | Ferrous targets |
| Assured operating distance | s a | 0 ... 1.62 mm |
| CCC approval | Certified by China Compulsory Certification (CCC) |
| Connection type | Connector plug |
| Degree of protection | IP67 / IP68 / IP69K - cordset dependent according to cable specification |
| Diameter | 12 mm |
| Error indicator | LED, green/yellow (Alternate Flashing) - Short circuit/overload indication |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Hysteresis | H | 3 ... 15 typ. 5 % |
| Installation | flush |
| Length | 85 mm |
| Length 85 mm Diameter 12 mm | Length | 85 mm | Diameter | 12 mm |
| Number of pins | 3 |
| Operation indicator | Dual LED Green: power Yellow: output |
| Output polarity | AC/DC |
| Output type | Two-wire |
| Rated operating distance | s n | 2 mm |
| Reduction factor r 304 | 0.4 - 0.7 |
| Reduction factor r Al | 0 |
| Reduction factor r Brass | 0 |
| Reduction factor r Cu | 0 |
| Reduction factor r St37 | 1 |
| Reverse polarity protection | yes |
| Sensing face | Stainless steel 1.4305 / AISI 303 |
| Short-circuit protection | yes |
| Standards | EN IEC 60947-5-2 |
| Standards EN IEC 60947-5-2 | Standards | EN IEC 60947-5-2 |
| Switching function | Normally open (NO) |
| Threading | 1/2"-20 UN |
| Threading 1/2"-20 UN Number of pins 3 | Threading | 1/2"-20 UN | Number of pins | 3 |
| UL approval | cULus Listed Load Type: Resistive Enclosure Type Rating: Type 1 Supply/Switching Voltage: 250 V AC/DC Output Switching Current: 200 mA |
Documents
No documents are linked to this part yet.