All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | ≤ 50 mA |
| Operating voltage | U B | 15 ... 30 V DC , ripple 10 % SS |
| AC and DC characteristics | |
| Load impedance | > 1 kOhm |
| Repeat accuracy | ± 0.1 % of full-scale value |
| Resolution | 0.35 mm |
| Response delay | approx. 125 ms |
| Transducer frequency | approx. 255 kHz |
| Environment and package | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Temperature influence | ± 1.5 % of full-scale value |
| Other | |
| Adjustment range | 90 ... 1000 mm |
| Beam width | wide |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Common mode operation | max. 40 Hz |
| Common mode operation max. 40 Hz Multiplex operation ≤ 40 Hz / n, n = number of sensors, n ≤ 5 | Common mode operation | max. 40 Hz | Multiplex operation | ≤ 40 Hz / n, n = number of sensors, n ≤ 5 |
| Connection type | Connector plug M12 x 1 , 5-pin |
| Dead band | 0 ... 70 mm |
| Degree of protection | IP67 |
| Deviation of the characteristic curve | ± 1 % of full-scale value |
| Diameter | 18 mm |
| Housing | brass, nickel-plated |
| Housing brass, nickel-plated Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam | Housing | brass, nickel-plated | Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Input type | 1 program input lower evaluation limit A1: -U B ... +1 V, upper evaluation limit A2: +4 V ... +U B input impedance: > 4.7 kΩ, pulse duration: ≥ 1 s |
| LED red | solid red: Error red, flashing: program function, object not detected |
| LED yellow | solid yellow: object in the evaluation range yellow, flashing: program function, object detected |
| Length | 75 mm |
| Length 75 mm Diameter 18 mm | Length | 75 mm | Diameter | 18 mm |
| Mass | 60 g |
| Multiplex operation | ≤ 40 Hz / n, n = number of sensors, n ≤ 5 |
| Output | evaluation limit A1: 90 mm evaluation limit A2: 1000 mm output function: rising ramp |
| Output type | 1 analog output 0 ... 10 V |
| Sensing range | 70 ... 1000 mm |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 | Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standard target plate | 100 mm x 100 mm |
| Synchronization | 1 synchronous connection, bi-directional 0-level: -U B ...+1 V 1-level: +4 V...+U B input impedance: > 12 kΩ synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| UL approval | cULus Listed, Class 2 Power Source |
Documents