All alternatives

View full report

Technical parameters

AC and DC characteristics
Repeat accuracy [mm]0.01
Environment and package
Height Z [mm]54.5
Max. ambient temperature [°C]90.0
Min. ambient temperature [°C]5.0
Other
Cleanroom class ISO 14644-15
Cleanroom class: ISO 14644-11999
Closing force [N]415.0
Closing force (with finger lengths of 0 mm) [N]485.0
Closing time [s]0.04
Cylinder volume per double stroke [cm³]22.5
Dustproof versionyes
IP protection class64
Length X [mm]108.0
Max. air purge pressure [bar]1.0
Max. axial force Fz max. [N]1500.0
Max. operating pressure [bar]8.0
Max. permissible finger length [mm]110.0
Max. permissible weight per finger [kg]0.6
Min. air purge pressure [bar]0.5
Min. operating pressure [bar]2.5
Moment Mx max. [Nm]60.0
Moment My max. [Nm]95.0
Moment Mz max. [Nm]55.0
Nominal operating pressure [bar]6.0
Opening force [N]465.0
Opening force (with finger lengths of 0 mm) [N]540.0
Opening time [s]0.04
Recommended workpiece weight [kg]2.1
Stroke per jaw [mm]8.0
Weight [kg]0.6
Width Y [mm]42.0

Documents