All alternatives

View full report

Technical parameters

Power
Current0 ... 10 A
Current limitapprox. 12 A
Rated operating currentI e | 4.0 A (115 V) 1.9 A (230 V)
Rated operating voltageU e | 115/230 V AC (for 115 V range, jumper) Range: 93 to 132 V AC/187 to 265 V AC
Voltage30 V ± 1 % Adjustment range 22.5 ... 29.5 V DC
AC and DC characteristics
Supply frequency47 ... 63 Hz
Environment and package
Ambient temperature-10 ... 70 °C (14 ... 158 °F) with free convection
Height132.5 mm
Height 132.5 mm Width 70 mm Length 140 mmHeight | 132.5 mm | Width | 70 mm | Length | 140 mm
MountingDIN mounting rail
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Other
Capacity factorapprox. 0.6 (Depending on input voltage)
ConnectionConnection terminals, max. conductor cross-section 0.5 to 2.5 mm 2 Stripping length 5 to 6 mm
Degree of protectionIEC 60529:2001
Directive 2014/30/EUEN 55011, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2 class A, EN 61000-3-3, EN 61010-1
Directive 2014/30/EU EN 55011, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2 class A, EN 61000-3-3, EN 61010-1Directive 2014/30/EU | EN 55011, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61000-3-2 class A, EN 61000-3-3, EN 61010-1
Directive 2014/35/EUEN 61010-1:2010
Directive 2014/35/EU EN 61010-1:2010Directive 2014/35/EU | EN 61010-1:2010
Efficiencyapprox. 89 %
Electromagnetic compatibilityEN 55011, EN 61000-6-1, EN 61000-6-2
Fusing6.3 AT
LED OverloadRed LED lights up for overload, flashes for hiccup mode
LED PWRLED green
Length140 mm
Massapprox. 1200 g
PotentiometerTop: Output current limitation (covered by a dummy plug) Bottom: Output voltage adjustment
Protection classI, Protective conductor connection necessary
StandardsHarmonic waves: EN 61000-3-2 Class A Interference suppression: EN 55022, EN 55011 Class B Electrostatic discharge (ESD): IEC 61000-4-2 (8 kV contact discharge, 15 kV air discharge) Electromagnetic fields: IEC 61000-4-3 (10 V/m) Burst: IEC 61000-4-4 (4 kV input, 2 kV output/capacitively coupled) Surge: IEC 61000-4-5 (4 kV asymmetrical, 4 kV symmetrical) Conducted interference: IEC 61000-4-6 (10 V, 150 kHz to 80 MHz)
UL File NumberE223176
Width70 mm

Documents

No documents are linked to this part yet.