All alternatives

View full report

Technical parameters

Power
1) Voltage Rating300 V RMS
Environment and package
1) Temperature Range-30 to 80°C
Other
1) CEEU Low Voltage Directive 2014/35/EU
(1) Color CodeAlpha Wire Color Code D
1) Component 13 X 1 COND
2) Bend Radius10X Cable Diameter
2) Cable Assembly3 Components Cabled
2) Capacitance39 pF/ft @1 kHz, Nominal Conductor to Conductor
3) California Proposition 65This product may contain substances known to the State of California to cause Cancer or Reproductive Harm, but is exempt from labeling based on the Consent Judgement. See the Alpha Wire website for more information.
3) Ground Capacitance70 pF/ft @1 kHz, Nominal
3) Pull Tension38 Lbs, Maximum
3) ShieldA/P/A Tape, 25% Overlap, Min.
4) Inductance0.19 μH/ft, Nominal
4) Sunlight ResistanceYes
5) Conductor DCR10.2 Ω/1000ft @20°C, Nominal
5) Direct BurialYes
6) OA Shield DCR3.3 Ω/1000ft @20°C, Nominal
a) Color(s)Slate, Black, Yellow, Orange, Blue, Green, Red, Sand Beige, White
a) Drain Wire20 (7/28) AWG Tinned Copper
a) Twists5.3 Twists/foot (min)
b) BraidTinned Copper,70% Coverage, Nom.
b) OrientationComponents to be arranged from INSIDE LAYER to OUTSIDE LAYER
b) Ripcord1 End 810 Denier Nylon
c) Core WrapClear Mylar Tape, 25% Overlap, Min.
ColorBLACK
Cond1
c) PrintALPHA WIRE-* P/N 35153 3C 20 AWG XTRAGUARD(R) 3 80C 300 VOLTS CE ROHS (SEQ FOOTAGE) * = Factory Code
Electrical Properties(For Engineering purposes only)
PackagingFlange x Traverse x Barrel (inches)

Documents