All alternatives

View full report

Technical parameters

AC and DC characteristics
Repeat accuracy [mm]0.01
Environment and package
Height Z [mm]49.0
Max. ambient temperature [°C]90.0
Min. ambient temperature [°C]5.0
Other
Closing force [N]230.0
Closing force (with finger lengths of 0 mm) [N]242.0
Closing time [s]0.03
Cylinder volume per double stroke [cm³]11.0
Diameter of center bore [mm]14.0
IP protection class40
Length X [mm]96.0
Max. air purge pressure [bar]1.0
Max. axial force Fz max. [N]1100.0
Max. operating pressure [bar]8.0
Max. permissible finger length [mm]80.0
Max. permissible weight per finger [kg]0.35
Min. air purge pressure [bar]0.5
Min. operating pressure [bar]2.5
Moment Mx max. [Nm]40.0
Moment My max. [Nm]60.0
Moment Mz max. [Nm]40.0
Nominal operating pressure [bar]6.0
Opening force [N]260.0
Opening force (with finger lengths of 0 mm) [N]270.0
Opening time [s]0.03
Recommended workpiece weight [kg]1.25
Stroke per jaw [mm]6.0
Weight [kg]0.47
Width Y [mm]42.0