Pepperl+Fuchs, Inc.Germany
2720
ActivePrint mark contrast sensor, 9.5 mm detection range, RGB light with rectangular light spot, external Teach-in, push-pull output, M12 plug
All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| No-load supply current | I 0 | ≤ 60 mA |
| Operating voltage | U B | 10 ... 30 V DC |
| Switching current | max. 200 mA |
| Switching voltage | PNP: ≥ (+U B -2.5 V) , NPN: ≤ 1.5 V |
| AC and DC characteristics | |
| Ripple | 10 % |
| Switching frequency | f | 16.5 kHz |
| Environment and package | |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Height | 85.6 mm |
| Height 85.6 mm Width 33 mm Depth 60.8 mm | Height | 85.6 mm | Width | 33 mm | Depth | 60.8 mm |
| Storage temperature | -20 ... 75 °C (-4 ... 167 °F) |
| Other | |
| Angle deviation | max. ± 3° |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Connection | 5-pin, M12 x 1 connector |
| Continuous light | 7000 Lux |
| Continuous light 7000 Lux | Continuous light | 7000 Lux |
| Control elements | Teach-In key |
| Degree of protection | IP67 |
| Depth | 60.8 mm |
| Diagnostic Coverage (DC) | 0 % |
| Function indicator | LED yellow; switching operation: lights up if print mark is detected Alarm display: flashing quickly, if no safe operation is possible |
| Function input | Teach-In input |
| Housing | PC (glass-fiber-reinforced Makrolon) |
| Housing PC (glass-fiber-reinforced Makrolon) Optical face glass | Housing | PC (glass-fiber-reinforced Makrolon) | Optical face | glass |
| Light source | LED |
| Light spot representation | 1 mm x 4 mm , light spot perpendicular to housing |
| Light type | Visible green/red/blue, modulated light |
| Mass | 200 g |
| Mission Time (T M ) | 20 a |
| MTTF d | 650 a |
| Optical face | glass |
| Product standard | EN 60947-5-2 |
| Response time | 30 µs |
| Sensor range | 9.5 mm ± 3 mm |
| Shock and impact resistance | IEC / EN 60068. half-sine, 40 g in each X, Y and Z directions |
| Signal output | Push-pull output, short-circuit protected, reverse polarity protected |
| Teach-in | Dynamic Teach-In |
| Vibration resistance | IEC / EN 60068-2-6. Sinus. 10 -150 Hz, 5 g in each X, Y and Z directions |
| Width | 33 mm |