All alternatives

View full report

Technical parameters

Power
Current consumptionelectrical connection E5: max. 30 mA, reverse-polarity-proof electrical connection WA: max. 130 mA
Rated voltageU r | electrical connection E5: 10.8 ... 45 V DC, short-term pulse on 55 V DC electrical connection WA: 20 ... 235 V AC, 50/60 Hz or 20 ... 55 V DC
AC and DC characteristics
Switch-on delayt on | correct switching after max. 1.5 s
Environment and package
Ambient temperature-40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) (Dust-Ex version)
Dimensionsmax. ∅94 mm (3.7 inch), length 391 mm (15.4 inch)
Influence of medium temperaturedepending on the filling material
Mounting locationThe capacitive limit switch can be installed in silos made of different materials (e. g. metal, plastic, concrete).
Process temperature-40 ... 130 °C (-40 ... 266 °F) -40 ... 80 °C (-40 ... 176 °F) (Dust-Ex version)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Other
Bulk density≤ 200 g/l
Climate classEN 60068, part 2-38 (test Z/AD)
Connectiongland M20 thread G1/2, NPT1/2
Construction typedevice with rod probe
Degree of protectionIEC 60529:2001
Designation- LCL-Z10 cover with sight glass for F14 housing - LCL-Z11 adapter for R1-1/2, EN 10226 - LCL-Z12 adapter for G1-1/2, DIN ISO 228 - LCL-Z13 adapter for NPT1-1/4, steel - LCL-Z15 adapter for NPT1-1/4, 1.4571
Directive 2014/30/EUEN 61326-1:2006 , EN 61326-2-3:2006
Directive 2014/30/EU EN 61326-1:2006 , EN 61326-2-3:2006Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-31:2009
Directive 2014/35/EUEN 61010-1:2010
Directive 2014/35/EU EN 61010-1:2010Directive 2014/35/EU | EN 61010-1:2010
Electromagnetic compatibilityNE 21
Equipment architectureThe measuring system consists of: - the device - a supply point - the connected control systems, switching units, signalling systems (e. g. lamps, horns, PCS, PLC, etc.)
EU-type examination certificatesee instruction manuals (SI)
Hysteresishorizontal 4 mm (0.16 inch), vertical 7 mm (0.28 inch)
Installation positionany position
Long-term drifthorizontal 3 mm (0.12 inch), vertical 6 mm (0.24 inch)
MaterialF14 housing: polyester PBT-FR F34 housing F34: aluminum Probe: PPS GF40
Measured variablelimit level (limit value)
Measuring methodA metal plate at the end of the probe, within the insulation, and the surroundings (e. g. the silo walls) combine to form the two electrodes of a capacitor. If the probe is covered or free of material, then the capacitance changes and the LCL switches.
Measuring rangedielectric constant ≥ 1.6
Medium pressure limits-1 ... 25 bar
Operating modeMAX = maximum safety: The device switches if the probe is covered or if the supply voltage is disconnected in a safety-oriented manner (signal on alarm). example application: overspill protection MIN = minimum safety: The device switches if the probe is uncovered or if the supply voltage is disconnected in a safetyoriented manner (signal on alarm). example application: dry-running protection
Output signalconnection E5: switching PNP, I max = 200 mA - overload and short circuit protection - residual voltage at transistor at I max < 2.9 V connection WA: contact change-over, potential-free - U max = 253 V - I max = 4 A (AC) - P max = 1000 VA, cos φ = 1, P max = 500 VA, cos φ > 0.7
Process connectionthread R1 acc. to EN 10226, BSPT, adapter for R1-1/2 and G1-1/2 see accessories thread NPT1 to ANSI B 1.20.1, adapter for NPT1-1/4 see accessories
Reference operating conditionsvessel type: plastic vessel, ambient temperature: 73 °F (23 °C, 296 K), medium temperature: 73 °F (23 °C, 296 K) medium pressure p e : 0 bar, medium: dielectric constant = 2.6, conductivity: < 1 µS sensitivity setting: C
SeriesLCL1
Shock resistancedevice with F34 housing: 7 J
Signal on alarmconnection E5: < 100 µA connection WA: relay de-energized
Solid contents≤ ∅ 30 mm
State of aggregationsolids
Supplementary documentationtechnical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI)
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Surge protectionovervoltage category III
Switching timeapprox. 0.5 s when covering and uncovering the sensor
Vibration resistanceEN 60068-2-64

Documents

No documents are linked to this part yet.