Pepperl+Fuchs, Inc.Germany
139074
ActiveGateway module for fieldbus power hub for PROFIBUS PA to PRFIBUS DP Master communication
All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Power dissipation | 3 W |
| PROFIBUS DP/Supply | functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff |
| Rated current | I r | 150 ... 95 mA |
| Rated voltage | U r | 19.2 ... 30 V DC |
| Environment and package | |
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Design / Mounting | Motherboard based |
| Height | 106 mm |
| Height 106 mm Width 40 mm Depth 128 mm | Height | 106 mm | Width | 40 mm | Depth | 128 mm |
| Mounting | motherboard mounting |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Other | |
| All circuits/FE | functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff |
| Certificate | TÜV 04 ATEX 2500 X |
| CH/CH | functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff |
| CH/PROFIBUS DP | functional insulation acc. to IEC 62103, rated insulation voltage 50 V eff |
| Connection | 9-pin Sub-D socket |
| Connection 9-pin Sub-D socket Protocol PROFIBUS DP V1 | Connection | 9-pin Sub-D socket | Protocol | PROFIBUS DP V1 |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection | IEC 60529 |
| Depth | 128 mm |
| Directive 2014/30/EU | EN 61326-1:2013 |
| Directive 2014/30/EU EN 61326-1:2013 | Directive 2014/30/EU | EN 61326-1:2013 |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
| Directive 2014/34/EU EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 | Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010 |
| Directive 73/23/EEC | EN 50178 (identical to EN 62103) |
| Directive 73/23/EEC EN 50178 (identical to EN 62103) | Directive 73/23/EEC | EN 50178 (identical to EN 62103) |
| Electromagnetic compatibility | NE 21:2017 for simplex operating mode only |
| Fieldbus standard | IEC 61158-2 |
| Galvanic isolation | IEC 62103 |
| Housing material | Polycarbonate |
| IECEx certificate | IECEx TUN 13.0038X |
| IECEx certificate IECEx TUN 13.0038X IECEx marking Ex nA IIC T4 Gc | IECEx certificate | IECEx TUN 13.0038X | IECEx marking | Ex nA IIC T4 Gc |
| IECEx marking | Ex nA IIC T4 Gc |
| Installation in hazardous area | Zone 2 / Div. 2 |
| LED DP/ERR | red 2 Hz flashing: DP error ; red: Hardware error |
| LED PWR | green: Power on |
| LED Red. | yellow: redundant operation primary device ; yellow 2 Hz flashing: synchronization or redundancy not available |
| LED Seg 1...4 | red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error |
| Marking | II 3 G Ex nA IIC T4 Gc |
| Marking II 3 G Ex nA IIC T4 Gc | Marking | II 3 G Ex nA IIC T4 Gc |
| Mass | 250 g |
| Number of segments | 4 |
| Pollution degree | max. 2, according to IEC 60664 |
| Protocol | PROFIBUS DP V1 |
| Relative humidity | < 95 % non-condensing |
| Shock resistance | EN 60068-2-27 |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Vibration resistance | EN 60068-2-6 |
| Width | 40 mm |
Documents