All alternatives

View full report

Technical parameters

AC and DC characteristics
Repeat accuracy [mm]0.05
Environment and package
Height Z [mm]146.9
High-temperature versionyes
Max. ambient temperature [°C]130.0
Min. ambient temperature [°C]5.0
Other
Cleanroom class ISO 14644-15
Cleanroom class: ISO 14644-11999
Closing time [s]1.8
Cylinder volume per double stroke [cm³]1725.0
Diameter D [mm]295.3
IP protection class67
Max. air purge pressure [bar]0.5
Max. axial force Fz max. [N]3750.0
Max. operating pressure [bar]6.5
Max. permissible finger length [mm]100.0
Max. permissible weight per finger [kg]5.5
Min. air purge pressure [bar]0.2
Min. operating pressure [bar]4.0
Min. spring force [N]4740.0
Moment Mx max. [Nm]135.0
Moment My max. [Nm]150.0
Moment Mz max. [Nm]105.0
Nominal operating pressure [bar]6.0
Opening force [N]17150.0
Opening force (with finger lengths of 0 mm) [N]20450.0
Opening time [s]1.2
Recommended workpiece weight [kg]60.0
Stroke per jaw [mm]14.0
Weight [kg]20.1

Documents