All alternatives

View full report

Technical parameters

Power
Current consumptionelectronic insert FEL42: ≤ 10 mA, without load
Power consumptionelectronic insert FEL42: ≤ 0,5 W electronic insert FEL44: ≤ 25 VA/< 1.3 W electronic insert FEL48: acc. to IEC 60947-5-6 (NAMUR)
Rated voltageU r | electronic insert FEL42: 10 V DC ... 55 V DC electronic insert FEL44: 19 V AC ... 253 V AC/19 V DC ... 55 V DC electronic insert FEL48: switch amplifier acc. to IEC 60947-5-6 (NAMUR)
Environment and package
Ambient temperature-40 ... 70 °C (-40 ... 158 °F) For further information see technical information (TI).
Dimensionshousing: diameter max. 101 mm, heigth max. 118 mm compact version: length depends on process connection short tube version: length 99 ... 118 mm, depends on process connection tube extension: length 117 ... 2000 mm tuning fork: width 17.2 mm, fork width 10 mm, length 40 mm For further information see technical information (TI).
Influence of medium temperaturemax. +1.4 ... -2.8 mm (-40 ... 150 °C (-40 ... 302 °F))
Medium temperature-40 ... 150 °C (-40 ... 302 °F)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Thermal shock resistance≤ 120 K/s
Other
Altitude≤ 2000 m above MSL
Climate classIEC 60068-2-38 test Z/AD
Connectiongland M20 thread M20 , G1/2 , NPT1/2 , NPT3/4 plug M12
Construction typecompact device
Control elementsswitches on the electronic insert
Corrosion resistanceacc. to ISA-71.04, severity level G3
CSA approvalsee instruction manuals
Degree of protectionIEC 60529 , NEMA 250
Densitymin. 0.5 g/cm 3 , optional 0.4 g/cm 3
Designationsee technical information (TI)
Directive 2014/30/EUEN 61326
Directive 2014/30/EU EN 61326Directive 2014/30/EU | EN 61326
Directive 2014/35/EUEN 61010-1
Directive 2014/35/EU EN 61010-1Directive 2014/35/EU | EN 61010-1
Display elementswithout display
Electromagnetic compatibilityNE 21
EU-type examination certificatesee instruction manuals
Function principlepoint level detection, maximum or minimum detection for liquids
Function testvia switches on the electronic insert
Housingsingle compartment, aluminum, coated single compartment, plastic
Hysteresistyp. 2.5 mm
IECEx approvalsee instruction manuals
Influence of medium densitysee technical information (TI)
Influence of medium pressuremax. 0 ... 2.6 mm (-1 ... 40 bar)
Installation positionany position
Installation position any positionInstallation position | any position
Massbasic weight: 0.65 kg the basic weight comprises: - sensor (compact) - electronic insert - housing: single compartment, plastic with cover - process connection: thread, G3/4 in addition to the basic weight: - housing: single compartment, aluminum, coated: 0.8 kg - pipe extension: 1000 mm: 0.9 kg, 100 inch: 2.3 kg - plastic protective cover: 0.2 kg For further information see technical information (TI).
Materialsee technical information (TI)
Maximum measured errormax. ± 1 mm
Measured variablelimit level (limit value)
Measuring methodThe change in vibration frequency causes the device to switch.
Measuring rangedepends on installation location and the tube extension maxmum sensor length : 2 m
Medium densityadjustment on the electronic insert > 0,5 g/cm 3 or > 0,7 g/cm 3 (other on request)
Medium pressurep e = -1 ... 40 bar (-14.5 ... 580.2 psi) over the entire temperature range , exceptions see process connections
Output typeelectronic insert FEL42: 3-wire PNP electronic insert FEL44: relay DPDT electronic insert FEL48: 2-wire NAMUR
Overspill protectionsee approval (ZE)
Process connectioncylindrical threads G3/4, G1 acc. to DIN ISO 228 G for installing in weld-in adapter cylindrical threads G3/4, G1 acc. to DIN ISO 228 G with flat seal conical threads NPT3/4, NPT1 acc. to ANSI B 1.20.3 conical threads R3/4, R1 acc. to EN 10226 flanges RF, RJF, FF from 1 inch acc. to ASME B16.5 flanges form A, B1, C, D, E from DN25 acc. to EN 1092-1 flanges RF from 10K 25A acc. to JIS B2220 Tri-Clamp from DN25 acc. to ISO 2852 For further information see technical information (TI).
Reference operating conditionsambient temperature: 23 °C (73 °F) process temperature: 23 °C (73 °F) density: 1 g/cm 3 (water) medium viscosity: 1 mPa·s process pressure: ambietn pressure/unpressurized sensor installation: verticaly from above density selection switch: > 0.7 g/cm 3 switch direction of sensor: uncovered to covered
SeriesVibracon LVL-M3
Shock resistanceIEC 60068-2-27
State of aggregationliquid
Supplementary documentationtechnical information (TI) manuals, brief instructions (BA, KA) instruction manuals Special documentation (SD)
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Surface qualityR a < 3.2 µm/126 µinch
Switch behaviourswitch-over for minimum/maximum residual current safety on electronic insert MAX = maximum safety: The output switches to the power fail response when the fork is covered. for use with overspill protection for example MIN = minimum safety: The output switches to the power fail response when the fork is exposed. for use with dry running protection for example
Switching pointsee section switch point
Test pressurePN = 40 bar (580 psi): test pressure = 1.5 x PN max. 60 bar (870 psi) dependent on the process connection selected
Vibration resistanceEN 60068-2-64
Viscositymax. 10000 mm 2 /s (max. 10000 cSt)

Documents

No documents are linked to this part yet.