Power
No-load supply currentI 0 | < 30 mA at 24 V Operating voltage
Operating voltageU B | 24 ... 240 V AC/DC
Power consumptionP 0 | ≤ 3.5 VA
Rated impulse withstand voltageU imp | 2500 V
Rated insulation voltageU i | 250 V
Rated insulation voltage U i 250 V Rated impulse withstand voltage U imp 2500 VRated insulation voltage | U i | 250 V | Rated impulse withstand voltage | U imp | 2500 V
Switching currentmax. 2.5 A , see section characteristic curve
Switching powerDC: max. 95 W AC: max. 600 VA
Switching voltagemax. 240 V AC/DC
AC and DC characteristics
Switching frequencyf | 25 Hz
Environment and package
Ambient temperature-30 ... 60 °C (-22 ... 140 °F) , cable, fixed installation -20 ... 60 °C (-4 ... 140 °F) , movable cable not appropriate for conveyor chains
Height61.9 mm
Height 61.9 mm Width 20 mm Depth 41.7 mmHeight | 61.9 mm | Width | 20 mm | Depth | 41.7 mm
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Other
Ambient light limitEN 60947-5-2 : 60000 Lux
Cable length2 m
Connection2 m fixed cable
Control elementsLight-on/dark-on changeover switch
Degree of protectionIP67
Depth41.7 mm
Diagnostic Coverage (DC)0 %
Diameter of the light spotapprox. 300 mm at a distance of 10 m
Effective detection range0 ... 10 m
Function indicatorYellow LED: Permanently lit - light path clear Permanently off - object detected Flashing (4 Hz) - insufficient operating reserve Flashing (8 Hz) - fault detected, the outputs maintain the status
FuseSafety fuse ≤ 2 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly.
HousingPC (Polycarbonate)
Housing PC (Polycarbonate) Optical face PMMAHousing | PC (Polycarbonate) | Optical face | PMMA
LED risk group labellingexempt group
Light sourceLED
Light typemodulated visible red light
Massapprox. 120 g
Mission Time (T M )20 a
MTTF d642 a
Opening angle2 °
Operation indicatorLED green: power on
Optical facePMMA
Polarization filteryes
Pollution degree3
Product standardEN 60947-5-2 , EN 60947-1
Protection classII
Reference targetH85-2 reflector
Reflector distance0.05 ... 10 m
Response time≤ 20 ms
Signal outputRelay, 1 alternator
Switching typeThe switching type of the sensor is adjustable. The default setting is: Q - BK: normally-open / dark-on /Q - GY: normally-closed / light-on C - WH: Common
Threshold detection range12 m
UL approvalE87056 , cULus Listed
Usage categoryDC-12 , DC-13 , AC-12 u. AC-140
Width20 mm

Documents