Pepperl+Fuchs, Inc.Germany
118431
ActiveVibration sensor with switching output and analog current output
All alternatives
View full reportTechnical parameters
| Power | |
|---|---|
| Current consumption | max. 220 mA |
| Operating current | ≤ 100 mA |
| Operating voltage | U B | 18 ... 30 V DC |
| Output current | 4 ... 20 mA |
| Power consumption | P 0 | max. 6.6 W |
| Voltage drop | < 2 V |
| AC and DC characteristics | |
| Frequency range | 10 ... 1000 Hz |
| Measurement accuracy | ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s |
| Time delay before availability | t v | 2 s (rms filter is calculated intially with measurement data before they are available at the output) |
| Environment and package | |
| Ambient temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Maximum permissible ambient temperature | max. 80 °C (max. 176 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Other | |
| Averaging time | for v-rms: 2 s |
| Connection type | plug |
| Cross-sensitivity | < 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis |
| Degree of protection | DIN EN 60529, IP66, IP67 |
| Diagnostic Coverage (DC) | 0 % |
| Diameter | 23.8 mm |
| Fusing | external fuse is required: 1 A , fast acting , 30 V DC |
| Housing material | Stainless steel 1.4305 / AISI 303 |
| Length | 72.5 mm |
| Length 72.5 mm Diameter 23.8 mm | Length | 72.5 mm | Diameter | 23.8 mm |
| Load resistor | ≤ 500 Ω |
| Mass | approx. 100 g |
| Measured variable | Vibration velocity |
| Measuring technology | MEMS |
| Mission Time (T M ) | 20 a |
| MTTF d | 329 a |
| Number of pins | 4 |
| Ordinary Location | E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only. adapters providing field wiring on request |
| Output type | analog output, current output of the vibration variable |
| Preset response time | 2 s (minimum time for a vibration event above the switching threshold so that the output switches) |
| Series | Performance Line |
| Shock resistance | DIN EN 60068-2-27, 60 g , 6 ms |
| Short-circuit protection | yes |
| Surge protection | up to 2 kV |
| Switching function | Normally closed (NC) |
| Switching threshold | 1.6 mm/s ( 10 % of the measuring range ) |
| Threading | M12 |
| Threading M12 Number of pins 4 | Threading | M12 | Number of pins | 4 |
| Type | Vibration sensor |
| Vibration evaluation | DIN ISO 10816/20816 |
| Vibration resistance | DIN EN 60068-2-6, 16.5 g, 10 ... 1000 Hz |
| Vibration velocity | v-rms | 0 ... 16 mm/s |
| Vibration velocity v-rms 0 ... 16 mm/s | Vibration velocity | v-rms | 0 ... 16 mm/s |
Documents
No documents are linked to this part yet.