All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | ≤ 11 mA
Operating currentI L | 0 ... 200 mA
Operating voltageU B | 10 ... 60 V
Voltage dropU d | ≤ 3 V
Voltage drop I L = 100 mA, switching element onU d | 1.2 ... 2.5 V
Voltage drop I L = 100 mA, switching element on U d 1.2 ... 2.5 VVoltage drop I L = 100 mA, switching element on | U d | 1.2 ... 2.5 V
AC and DC characteristics
Switching frequencyf | 0 ... 3000 Hz
Time delay before availabilityt v | ≤ 20 ms
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Other
Actual operating distances r | 1.8 ... 2.2 mm typ.
Assured operating distances a | 0 ... 1.62 mm
Bending radius> 10 x cable diameter
Cable diameter4.8 mm ± 0.2 mm
CCC approvalCertified by China Compulsory Certification (CCC)
Colorblack
Connection typecable
Core cross section0.34 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Diameter12 mm
Housing materialStainless steel 1.4305 / AISI 303
HysteresisH | 1 ... 10 % typ. 3 %
Installationflush
LengthL | 2 m
Length 40 mm Diameter 12 mmLength | 40 mm | Diameter | 12 mm
MaterialPUR
Mission Time (T M )20 a
MTTF d1200 a
Number of cores3
Output polarityDC
Output typeNPN
Rated operating distances n | 2 mm
Reduction factor r 3040.7
Reduction factor r Al0.23
Reduction factor r Cu0.21
Reverse polarity protectionreverse polarity protected
Scope of delivery2 self locking nuts in scope of delivery
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functionNormally open (NO)
Switching state indicatorLED, yellow
UL approvalcULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 200 mA
Wire end ferrulesyes

Documents