All alternatives

View full report

Technical parameters

Power
Lowest operating currentI m | 2 mA
Off-state currentI r | 0 ... 0.5 mA typ.
Operating currentI L | 2 ... 100 mA
Operating voltageU B | 5 ... 60 V
Voltage dropU d | ≤ 5 V
AC and DC characteristics
Switching frequencyf | 0 ... 150 Hz
Time delay before availabilityt v | ≤
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Other
Actual operating distances r | 9 ... 11 mm typ.
Assured operating distances a | 0 ... 8.1 mm
Bending radius> 10 x cable diameter
Cable diameter4.8 mm ± 0.2 mm
CCC approvalCertified by China Compulsory Certification (CCC)
Colorblack
Connection typecable
Core cross section0.34 mm 2
Degree of protectionIP67
Diagnostic Coverage (DC)0 %
Diameter30 mm
Housing materialStainless steel 1.4305 / AISI 303
HysteresisH | 1 ... 10 % typ. 5 %
Installationflush
LengthL | 2 m
Length 40 mm Diameter 30 mmLength | 40 mm | Diameter | 30 mm
MaterialPUR
Mission Time (T M )20 a
MTTF d1830 a
Number of cores2
Output polarityDC
Output typeTwo-wire
Rated operating distances n | 10 mm
Reduction factor r 3040.7
Reduction factor r Al0.32
Reduction factor r Cu0.28
Reverse polarity protectionreverse polarity tolerant
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 61000-6-2:2019-02 EN IEC 61000-6-3:2021-03
Standards EN IEC 61000-6-2:2019-02 EN IEC 61000-6-3:2021-03Standards | EN IEC 61000-6-2:2019-02 EN IEC 61000-6-3:2021-03
Switching functionNormally open (NO)
Switching state indicatorall direction LED, yellow
UL approvalcULus Listed Load Type: General Purpose Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 100 mA
Wire end ferrulesyes

Documents

No documents are linked to this part yet.