All alternatives

View full report

Technical parameters

Power
No-load supply currentI 0 | ≤ 9 mA
Off-state currentI r | 0 ... 0.5 mA typ. 0.01 mA
Operating currentI L | 0 ... 400 mA
Operating voltageU B | 10 ... 60 V
Voltage dropU d | ≤ 2.8 V
Voltage drop I L = 100 mA, switching element onU d | 1 ... 2.6 V typ. 1.8 V
Voltage drop I L = 10 mA, switching element onU d | 0.9 ... 2.4 V typ. 1.7 V
Voltage drop I L = 200 mA, switching element onU d | 1.2 ... 2.8 V typ. 2 V
Voltage drop I L = 20 mA, switching element onU d | 0.9 ... 2.4 V typ. 1.7 V
Voltage drop I L = 50 mA, switching element onU d | 0.9 ... 2.5 V typ. 1.7 V
AC and DC characteristics
Switching frequencyf | 0 ... 500 Hz
Environment and package
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Other
Actual operating distances r | 9 ... 11 mm typ. 10 mm
Assured operating distances a | 0 ... 8.1 mm
Bending radius> 10 x cable diameter
Cable diameter6.8 mm ± 0.2 mm
Colorgrey
Connection typecable
Core cross section0.75 mm 2
Degree of protectionIP68
Diagnostic Coverage (DC)0 %
Diameter30 mm
Housing materialPBT
HysteresisH | typ. 5 %
Installationflush
LengthL | 10 m
Length 50 mm Diameter 30 mmLength | 50 mm | Diameter | 30 mm
MaterialPVC
Mission Time (T M )20 a
MTTF d1130 a
Number of cores4
Output polarityDC
Output typePNP
Rated operating distances n | 10 mm
Reduction factor r 3040.71
Reduction factor r Al0.4
Reduction factor r Brass0.45
Reduction factor r Cu0.38
Reverse polarity protectionreverse polarity protected
Sensing facePBT
Short-circuit protectionpulsing
StandardsEN IEC 60947-5-2
Standards EN IEC 60947-5-2Standards | EN IEC 60947-5-2
Switching functioncomplementary
Switching state indicatorLED, yellow
UL approvalcULus Listed Load Type: Resistive Circuitry: Class 2 Power Source Enclosure Type Rating: Type 1 Supply/Switching Voltage: 60 V DC Output Switching Current: 400 mA
Wire end ferrulesyes

Documents

No documents are linked to this part yet.